Pulse Generator, Unipolar, Demand
510(k) K772240
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK772240 | Date30 Jan 1978 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DXY
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.3610
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
This device is an Implantable Pacemaker Pulse-Generator, classified as a Class III medical device under FDA regulations. It delivers electrical impulses to regulate heart rhythm in patients with bradycardia or other conduction disorders, operating on a unipolar demand mode to ensure pacing only when intrinsic cardiac activity falls below predefined thresholds.
The Pulse Generator is implanted subcutaneously and designed for long-term use, requiring no user intervention beyond initial surgical placement. Supplied sterile and intended for single-patient use, it adheres to FDA clearance (510K, K772240) and regulatory standards under 870.3610. Compatibility with MRI environments is not specified, and device sizing is standardized for internal implantation without external modifications.
Other devices from Cardiac Pacemakers, Inc.
Questions
AI-generated answers, 18 Sep 2026
What is the primary purpose of this pulse generator in clinical practice, and how does its unipolar demand mode function differ from other pacing modes?
This pulse generator is designed to regulate heart rhythm in patients with bradycardia or conduction disorders by delivering electrical impulses only when the heart’s natural rhythm falls below predefined thresholds. The unipolar demand mode ensures pacing is triggered *only* when intrinsic cardiac activity is insufficient, minimizing unnecessary stimulation while maintaining consistent rhythm support. This contrasts with non-demand modes, which may pace continuously regardless of the heart’s activity.
Is this device intended for reuse, or is it strictly single-patient use? How does sterility factor into its supply and handling?
The device is supplied sterile and explicitly intended for single-patient use only, per manufacturer guidelines. Sterility is preserved through packaging designed for one-time implantation, eliminating the need for reprocessing or reuse. Clinicians must adhere to sterile surgical techniques during implantation to maintain integrity and prevent infection.
What considerations should clinicians keep in mind regarding storage and handling before and after surgical implantation?
Since the device is sterile and single-use, it must be stored in its original, unopened packaging in a clean, dry environment away from direct sunlight or extreme temperatures. Post-implantation, the generator is implanted subcutaneously and does not require additional handling beyond standard postoperative care. Avoid exposing the device to MRI environments unless explicitly validated by the manufacturer, as compatibility is not specified.
Are there multiple sizes or models available for this pulse generator, or is it a standardized implantable unit?
The device is described as a standardized implantable pulse generator, with no mention of variable sizes or models for internal implantation. It is designed for subcutaneous placement without external modifications, meaning clinicians select a single model based on compatibility with the patient’s pacing leads and clinical needs rather than sizing adjustments.