Skip to content

Pulse Oximeter

by Edan Instruments, Inc.

Ref H100B

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

Not listed

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 25 Oct 2026

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source EUDAMED, FDA 510(k), GUDID, synced 25 Oct 2026. What this means

Regulatory status

as of registry sync 25 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number69444138H100SF9 Basic UDI-DI 06944413800557UDI-DIDate29 Jan 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number06944413800557 UDI-DI Date1 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k) 510(k) NumberK092727 Date3 Dec 2009IssuedStatusActive

Certificates

0 certificates · EUDAMED

EUDAMED lists no certificate for this device's Basic UDI-DI.

A certificate issued for a device group may exist without being linked here.

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 25 Oct 2026.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • United States FDA 510(k) Active
  • European Union CE/MDR Active

Specification

EUDAMED · 510(k) · GUDID

Generic Name
Pulse oximeter
Model / Reference
H100B
Primary DI / UDI-DI
06944413800557
Basic UDI-DI
69444138H100SF9
510(k) Number
FDA Product Code
DQA
EMDN Code
Z1203020408 Pulse oximeters
GMDN Term
Pulse oximeter
Device Class
Class IIb EUDAMED
Class II GUDID
Regulation Number
870.2700
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device ClassEUDAMED
Class IIb
GUDID
Class II

Manufacturer details

EUDAMED SRN
CN-MF-000009957
Authorised representative
Shanghai International Holding Corp. GmbH(Europe) DE-AR-000000001

Other devices from Edan Instruments, Inc.

See all devices from Edan Instruments, Inc. →

Properties

  • Measuring Function
  • Prescription Use
  • Serial Number
  • Manufacturing Date

Other properties (20)

  • Sterile: No
  • Single Use: No
  • Implantable: No
  • Reusable: No
  • Contains Latex: No
  • Reprocessed: No
  • CMR Substance: No
  • Human-derived: No
  • Human Tissues: No
  • Animal Tissues: No
  • Endocrine Disruptor: No
  • Administering Medicine: No
  • Incorporates Medicinal Product: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Lot / Batch Number: No
  • Expiration Date: No