Pulse Oximeter System MODEL 7500, 8000AA, PCS-AU
by Nonin Medical, Inc. 17 variants
Ref 7500-0204, 7500-0803, 7500-1301, 7500-1702, 7500-1502, 7500-1601, 7500-1603, 7500-0005, 7500-0101, 7500-1501, 7500-1101, 7500-0301, 7500-1302, 7500-1203, 7500-0302, 7500-1304, 7500-0102, 7500-0203, 7500-1403, 7500-1401, 7500-1201, 7500-0404, 7500-0504, 7500-0201Model MODEL 7500, 8000AA, PCS-AU, MODEL 7500, 8000J, PCS-EU, MODEL 7500, 8000SS-3, PCS-US, MODEL 7500, 8000SL-3, PCS-UK, MODEL 7500, 8000SM-3, PCS-UK, MODEL 7500, 8000SL, PCS-USPulse Oximeter System, MODEL 7500, 8000SL, PCS-EU, MODEL 7500, NO SENSOR, PCS-AU, MODEL 7500, 8000AA-3, PCS-US, MODEL 7500, 8000SM-3, PCS-US, MODEL 7500, 8008J, PCS-US, MODEL 7500, 8000AA-2, PCS-US, MODEL 7500, 8000SS-3, PCS-UK, MODEL 7500, 8000SS, PCS-EU, MODEL 7500, 8000AA-2, PCS-UK, MODEL 7500, 8000SS-3, PCS-AU, MODEL 7500, 8000AA-3, PCS-UK, MODEL 7500, 8000AA, PCS-EU, MODEL 7500, 8000SM, PCS-EU, MODEL 7500, 8000SM, PCS-US, MODEL 7500, 8000SS, PCS-US, MODEL 7500, 8000AP, PCS-AU, MODEL 7500, 8000AP-3, PCS-AU, MODEL 7500, 8000AA, PCS-US
Active
Valid until
Not listed
FDA recalls
None foundTrust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00849686066883 | Date12 Dec 2024 | StatusActive |
| United States | FDA 510(k) 510(k) | NumberK191403 | Date20 Dec 2019 | StatusActive |
Certificates
EUDAMED lists no certificate for this device's Basic UDI-DI.
Recalls
No FDA recalls found in the data synced 24 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- United States
- European Union
Specification
- Full name
- Pulse Oximeter System
- Model / Reference
- MODEL 7500, 8000AA, PCS-AU, 7500-0204, 8000J, PCS-EU, 7500-0803, 8000SS-3, PCS-US, 7500-1301, 8000SL-3, PCS-UK, 7500-1702, 8000SM-3, 7500-1502, 8000SL, PCS-USPulse Oximeter System, 7500-1601, 7500-1603, NO SENSOR, 7500-0005, 8000AA-3, 7500-0101, 7500-1501, 8008J, 7500-1101, 8000AA-2, 7500-0301, 7500-1302, 8000SS, 7500-1203, 7500-0302, 7500-1304, 7500-0102, 7500-0203, 8000SM, 7500-1403, 7500-1401, 7500-1201, 8000AP, 7500-0404, 8000AP-3, 7500-0504, 7500-0201
- Primary DI / UDI-DI
- 00849686066883, 00849686098457, 00833166004977, 00849686098358, 00833166007633, 00833166007664, 00849686098365, 00849686066111, 00833166002683, 00833166002829, 00833166002799, 00849686066746, 00833166007565, 00849686098402, 00849686098532, 00849686066814, 00833166002690, 00849686098549, 00849686098389, 00833166004960, 00849686066708, 00849686066869, 00849686066852, 00833166007183
- Basic UDI-DI
- B-00849686066883, B-00849686098457, B-00833166004977, B-00849686098358, B-00833166007633, B-00833166007664, B-00849686098365, B-00849686066111, B-00833166002683, B-00833166002829, B-00833166002799, B-00849686066746, B-00833166007565, B-00849686098402, B-00849686098532, B-00849686066814, B-00833166002690, B-00849686098549, B-00849686098389, B-00833166004960, B-00849686066708, B-00849686066869, B-00849686066852, B-00833166007183
- EMDN Code
- Z1203020408, C900301
- Device Class
- Class IIb
- EU market of registration
- Netherlands
Manufacturer details
- EUDAMED SRN
- US-MF-000008228
- Authorised representative
- MPS Medical Product Service GmbH DE-AR-000005009
Overview
AI-generated summary, 18 Sep 2026
This device is a Pulse Oximeter System (Nomenclature Code: Z1203020408), a Class IIb medical device designed to non-invasively measure oxygen saturation (SpO₂) in arterial blood and pulse rate. It employs photoplethysmography to detect light absorption variations in tissue, providing real-time monitoring of oxygenation levels and heart rate for clinical assessment.
The system is non-sterile, non-reusable, and non-implantable, intended for single-use applications in hospital, clinical, and home-care settings. It operates without active medication administration or latex components and is supplied with a unique Basic UDI (B-00849686066883) for traceability. Authorized under FDA 510(k) and MDD compliance, it adheres to regulatory standards for non-invasive monitoring devices.
Other devices from Nonin Medical, Inc.
Questions
AI-generated answers, 18 Sep 2026
What clinical measurements does this pulse oximeter system provide, and how does it achieve them?
This Pulse Oximeter System measures oxygen saturation (SpO₂) in arterial blood and pulse rate non-invasively. It uses photoplethysmography, a technique that detects variations in light absorption by tissue to monitor oxygenation levels and heart rate in real time, enabling clinical assessment without medication administration or invasive procedures.
Is this device reusable, and if not, what are the implications for clinical settings?
No, this Pulse Oximeter System is designed for **single-use only** and is explicitly marked as non-reusable. Clinicians should dispose of it after one use to ensure patient safety and compliance with regulatory standards, particularly in hospital, clinical, or home-care environments where sterility and infection control are critical.
What models are available, and how can I identify the correct UDI for traceability?
The system comes in three models: **7500, 8000AA, and PCS-AU**. Each model is traceable via its unique **Basic UDI (B-00849686066883)** and associated UDI data (e.g., `01JEXPXYTAEY9VFS57Z2S5DEB9`), ensuring compliance with regulatory requirements for device tracking in healthcare settings.
Does this device contain latex or animal-derived components, and what are the storage requirements?
The Pulse Oximeter System is **latex-free** and does not contain animal tissues. Since it is **non-sterile and single-use**, storage should follow manufacturer guidelines to maintain functionality—typically in a clean, dry environment away from direct sunlight or extreme temperatures until use.
How does this device comply with regulatory standards, and who is the authorized representative in Europe?
The device is authorized under **FDA 510(k)** and **MDD compliance**, meeting regulatory standards for non-invasive monitoring. In Europe, **MPS Medical Product Service GmbH (SRN: DE-AR-000005009)** serves as the authorized representative, ensuring adherence to local market requirements.
Properties
Other properties (10)
- Sterile: No
- Implantable: No
- Reusable: No
- Contains Latex: No
- Reprocessed: No
- Human-derived: No
- Human Tissues: No
- Animal Tissues: No
- Administering Medicine: No
- Incorporates Medicinal Product: No