PV-LAB Model PVL-1 Peripheral Vascular System

by Electro-Diagnostic Instruments

510(k) K871912

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK871912 Date18 Feb 1988ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DPT
Device Class
Class II
Regulation
21 CFR Part 870.2120
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The PV-LAB Model PVL-1 is a blood-flow probe designed for extravascular peripheral vascular assessment. Classified as a Class II device, it measures blood flow dynamics in peripheral arteries to evaluate vascular function, supporting diagnostic evaluations for peripheral artery disease (PAD).

This device is supplied as a reusable diagnostic tool, intended for use in clinical settings such as cardiovascular laboratories. It operates in conjunction with complementary diagnostic systems (e.g., air plethysmography, Doppler, or PPG) to assess segmental arterial function. Authorized under FDA 510(k) clearance (K871912), it adheres to regulatory standards for cardiovascular diagnostic equipment, with no specific MRI safety or sterility requirements noted in the data.

Other devices from Electro-Diagnostic Instruments

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical scenarios is the PV-LAB Model PVL-1 primarily used for, and how does it function in those settings?

    The PV-LAB Model PVL-1 is designed for extravascular peripheral vascular assessment, specifically to measure blood flow dynamics in peripheral arteries. Clinicians use it to evaluate vascular function as part of diagnostic evaluations for peripheral artery disease (PAD). It operates alongside complementary systems like air plethysmography, Doppler, or photoplethysmography (PPG) to assess segmental arterial function, helping determine blood flow restrictions or occlusions in limbs.

  • Is the PV-LAB Model PVL-1 a single-use or reusable device, and what maintenance considerations should be noted?

    The PV-LAB Model PVL-1 is reusable, intended for use in clinical settings like cardiovascular laboratories. Since it lacks specific sterility requirements in the provided data, proper cleaning and maintenance protocols (e.g., disinfection between patients) should follow manufacturer guidelines to ensure accuracy and longevity. Reusability aligns with its design as a diagnostic tool for repeated use in vascular assessments.

  • What regulatory pathway was followed for FDA clearance of the PV-LAB Model PVL-1, and what does that mean for its use?

    The PV-LAB Model PVL-1 received FDA 510(k) clearance (K871912) under a traditional review pathway, classified as a Class II device with a substantially equivalent determination to a predicate device. This means it was deemed comparable to an existing approved device in terms of safety and effectiveness for its intended use—extravascular blood-flow measurement in peripheral arteries—and is authorized for use in clinical settings adhering to cardiovascular diagnostic standards.

  • Are there any size or model variations for the PV-LAB Model PVL-1, or is it a single standardized probe?

    The provided data only references the PV-LAB Model PVL-1 as a single standardized device, without mentioning alternative sizes or models. It is described as a blood-flow probe for peripheral vascular assessment, implying a uniform design for measuring arterial dynamics. For specific probe dimensions or technical specifications, refer to the manufacturer’s documentation.