PV-LAB Model PVL-1 Peripheral Vascular System
by Electro-Diagnostic Instruments
510(k) K871912
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK871912 | Date18 Feb 1988 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DPT
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.2120
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 19 Sep 2026
The PV-LAB Model PVL-1 is a blood-flow probe designed for extravascular peripheral vascular assessment. Classified as a Class II device, it measures blood flow dynamics in peripheral arteries to evaluate vascular function, supporting diagnostic evaluations for peripheral artery disease (PAD).
This device is supplied as a reusable diagnostic tool, intended for use in clinical settings such as cardiovascular laboratories. It operates in conjunction with complementary diagnostic systems (e.g., air plethysmography, Doppler, or PPG) to assess segmental arterial function. Authorized under FDA 510(k) clearance (K871912), it adheres to regulatory standards for cardiovascular diagnostic equipment, with no specific MRI safety or sterility requirements noted in the data.
Other devices from Electro-Diagnostic Instruments
Questions
AI-generated answers, 19 Sep 2026
What clinical scenarios is the PV-LAB Model PVL-1 primarily used for, and how does it function in those settings?
The PV-LAB Model PVL-1 is designed for extravascular peripheral vascular assessment, specifically to measure blood flow dynamics in peripheral arteries. Clinicians use it to evaluate vascular function as part of diagnostic evaluations for peripheral artery disease (PAD). It operates alongside complementary systems like air plethysmography, Doppler, or photoplethysmography (PPG) to assess segmental arterial function, helping determine blood flow restrictions or occlusions in limbs.
Is the PV-LAB Model PVL-1 a single-use or reusable device, and what maintenance considerations should be noted?
The PV-LAB Model PVL-1 is reusable, intended for use in clinical settings like cardiovascular laboratories. Since it lacks specific sterility requirements in the provided data, proper cleaning and maintenance protocols (e.g., disinfection between patients) should follow manufacturer guidelines to ensure accuracy and longevity. Reusability aligns with its design as a diagnostic tool for repeated use in vascular assessments.
What regulatory pathway was followed for FDA clearance of the PV-LAB Model PVL-1, and what does that mean for its use?
The PV-LAB Model PVL-1 received FDA 510(k) clearance (K871912) under a traditional review pathway, classified as a Class II device with a substantially equivalent determination to a predicate device. This means it was deemed comparable to an existing approved device in terms of safety and effectiveness for its intended use—extravascular blood-flow measurement in peripheral arteries—and is authorized for use in clinical settings adhering to cardiovascular diagnostic standards.
Are there any size or model variations for the PV-LAB Model PVL-1, or is it a single standardized probe?
The provided data only references the PV-LAB Model PVL-1 as a single standardized device, without mentioning alternative sizes or models. It is described as a blood-flow probe for peripheral vascular assessment, implying a uniform design for measuring arterial dynamics. For specific probe dimensions or technical specifications, refer to the manufacturer’s documentation.