QLAB Quantification System

by Philips Ultrasound LLC

Ref 795041

QLAB Quantification System (795041) is a radiological PACS-dedicated management software (EU MDR Class IIa; FDA Class II; FDA product code QIH, Automated Radiological Image Processing Software) made by Philips Ultrasound LLC, registered in EUDAMED on 24 May 2024 (Basic UDI-DI 0884838BM434SX) and listed in FDA GUDID since 29 May 2024 (UDI-DI 00884838122277), active as of 22 Oct 2026. One FDA recall is linked to it.

Active European Union. Also listed in GUDID (US).

CE MDR

Valid until

No date given

EUDAMED holds no validity date

FDA recalls

None ongoing

1 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing GUDID Number00884838122277 UDI-DI Date29 May 2024ListedStatusListed GUDID: in commercial distribution
European UnionCE/MDR EUDAMED Number0884838BM434SX Basic UDI-DI 00884838122277UDI-DIDate24 May 2024RegisteredStatusActive

Official records

From the FDA record

Device description
VM11.0 update
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

2 registries list this device

  • EUDAMED Basic UDI-DI 0884838BM434SX registered 24 May 2024 Active
  • FDA GUDID UDI-DI 00884838122277 listed 29 May 2024 Listed

Recalls

1 recall · FDA

    • Terminated Z-0815-2015 FDA Class II initiated 5 Nov 2014 catalog no. 795041 listed

    When using the QLAB Auto 2D Quantification (a2DQ) and Auto Cardiac Motion Quantification (aCMQ) applications, the reported End-Systolic Volume (ESV) may be smaller, and the Left Ventricular Ejection Fraction (EF) may be higher, than the ESV and EF calculated by manual tracing without the use of QLAB. An incorrect EF calculation could lead to misdiagnosis and/or delayed or incorrect therapy.

A catalog-number match means the recall lists this device's catalog or model number; the software version and lot are not checked.

Timeline

3 dated events

  1. Recall initiated FDA recalls Z-0815-2015
  2. Registered EUDAMED 0884838BM434SX
  3. Listed FDA GUDID 00884838122277

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Trade name
QLAB Quantification System EUDAMED
QLAB Advanced Quantification Software GUDID
Generic name
Radiological PACS-dedicated management software
Model / reference
795041
Primary DI / UDI-DI
00884838122277
Basic UDI-DI
0884838BM434SX
FDA product code
QIH
EMDN code
Z110603 Picture archiving and communication systems
GMDN term
Radiological PACS-dedicated management software
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.2050
System or procedure pack
System which is a device in itself
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
US-MF-000002237
Authorised representative
Philips Medical Systems Nederland B.V. NL-AR-000001422

Similar devices in this category

Other devices filed under PICTURE ARCHIVING AND COMMUNICATION SYSTEMS.

Other devices from Philips Ultrasound LLC

See all devices from Philips Ultrasound LLC →

Properties

  • Prescription use
  • Lot / batch number
Other properties (23, all answered No)