← Back to catalogue

QUANTA Lite® HA dsDNA ELISA

FDA UDI

Class II (US FDA UDI)

by Inova Diagnostics, Inc.

Identity

Trade Name
QUANTA Lite® HA dsDNA ELISA FDA UDI
Generic Name
Double stranded DNA antibody (anti-dsDNA) IVD, kit, enzyme immunoassay (EIA) FDA UDI
Device Name
1. Instruction leaflet: Giving full assay details. 2. QC Certificate: Indicating the expected performance of the batch. 3. C1q Coated Wells: 12 breakapart 8 well strips coated with human C1q. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches. 4. ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use. 5. C1q CIC Calibrators: 5 bottles, each containing 1.2mL of diluted aggregated human IgG, with the following concentrations of immune complex: 100, 33.3, 11.1, 3.7, 1.23 µg Eq/mL. Ready to use. 6. C1q CIC Positive Control: 1 bottle containing 1.2mL of diluted aggregated human IgG. The expected value is given on the QC certificate. Ready to use. 7. Type III Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored yellow, ready to use. 8. HRP Wash Concentrate: 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells. 9. HRP C1q CIC IgG Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgG. Colored blue. Ready to use. 10.TMB Chromogen: 1 bottle containing 10mL TMB chromogen. Ready to use. 11. HRP Stop Solution: 1 bottle containing 10mL of 0.344M Sulfuric Acid. Ready to use. FDA UDI
Model / Reference
704615 FDA UDI
Description
1. Instruction leaflet: Giving full assay details. 2. QC Certificate: Indicating the expected performance of the batch. 3. C1q Coated Wells: 12 breakapart 8 well strips coated with human C1q. Each plate is packaged in a re-sealable foil bag containing two desiccant pouches. 4. ELISA Negative Control: 1 bottle containing 1.2mL of diluted human serum. The expected value is given on the QC certificate. Ready to use. 5. C1q CIC Calibrators: 5 bottles, each containing 1.2mL of diluted aggregated human IgG, with the following concentrations of immune complex: 100, 33.3, 11.1, 3.7, 1.23 µg Eq/mL. Ready to use. 6. C1q CIC Positive Control: 1 bottle containing 1.2mL of diluted aggregated human IgG. The expected value is given on the QC certificate. Ready to use. 7. Type III Sample Diluent: 2 bottles containing 50mL of buffer for sample dilution. Colored yellow, ready to use. 8. HRP Wash Concentrate: 1 bottle containing 25mL of a 40-fold concentrated buffer for washing the wells. 9. HRP C1q CIC IgG Conjugate: 1 bottle containing 10mL of purified peroxidase labelled antibody to human IgG. Colored blue. Ready to use. 10.TMB Chromogen: 1 bottle containing 10mL TMB chromogen. Ready to use. 11. HRP Stop Solution: 1 bottle containing 10mL of 0.344M Sulfuric Acid. Ready to use. FDA UDI

Identifiers

Primary DI / UDI-DI
08426950593478 FDA UDI
510(k) Number
K062183 FDA UDI
FDA Product Code
LRM FDA UDI
GMDN Term
Double stranded DNA antibody (anti-dsDNA) IVD, kit, enzyme immunoassay (EIA) FDA UDI

Classification

Device Class
Class II FDA UDI
Regulation Number
866.5100 FDA UDI
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

No

FDA UDI

Single Use

Yes

FDA UDI

Implantable

No

FDA UDI

Contains Latex

No

FDA UDI

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

Yes

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

Yes

FDA UDI

Serial Number

No

FDA UDI

Expiration Date

Yes

FDA UDI

Manufacturing Date

No

FDA UDI

Category: Double stranded DNA antibody (anti-dsDNA) IVD, kit, enzyme immunoassay (EIA)

QUANTA Lite® HA dsDNA ELISA by Inova Diagnostics, Inc. — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS

Similar devices

Also classified as Double stranded DNA antibody (anti-dsDNA) IVD, kit, enzyme immunoassay (EIA).

Authorization Coverage (1 country)

Regulatory Authorizations

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Sources (1)

  • FDA UDI d9e8b316-83f9-4eac-91cd-9bd3ef004eba 36 fields · synced May 30, 2026