Skip to content

Quikclot IPN928798

by Teleflex Incorporated

Ref 636Model IPN928798

Quikclot IPN928798 (636) is a non-organic haemostatic agent (EU MDD Class III; FDA unclassified; FDA product code FRO, Dressing, wound, drug) made by Teleflex Incorporated, registered in EUDAMED on 22 Sep 2026 (Basic UDI-DI B-10841495150361), cleared under FDA 510(k) K123387 on 12 Apr 2013 and listed in FDA GUDID since 11 Jan 2024 (UDI-DI 10841495150361), active as of 23 Oct 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

2 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K123387

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-10841495150361 Basic UDI-DI 10841495150361UDI-DIDate22 Sep 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number10841495150361 UDI-DI Date11 Jan 2024ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK123387 Date12 Apr 2013DecidedStatusActive

Official records

From the FDA record

MRI safety
MR Safe
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-10841495150361 registered 22 Sep 2026 Active
  • FDA 510(k) K123387 decided 12 Apr 2013 Active
  • FDA GUDID UDI-DI 10841495150361 listed 11 Jan 2024 Listed

Recalls

2 recalls · FDA

    • Terminated Z-0925-2018 FDA Class II initiated 17 Nov 2017

    A customer complained that one of the pouches in a box of 10 had "QuikClot Roll" pouch instead of "QuikClot TraumaPad" pouch. The carton as well as the remaining 9 pouches were properly identified as QuikClot Trauma Pad. The customer alleged that when the pouch was opened, it contained a QuikClot TraumaPad. All 10 pouches in the box had the correct part number, lot number, and expiration date for the prod uct (QuikClot TraumaPad).

    • Terminated Z-2612-2017 FDA Class II initiated 17 May 2017

    Packaging breach may compromise sterility

Timeline

5 dated events

  1. Cleared FDA 510(k) K123387
  2. Recall initiated FDA recalls Z-2612-2017
  3. Recall initiated FDA recalls Z-0925-2018
  4. Listed FDA GUDID 10841495150361
  5. Registered EUDAMED B-10841495150361

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
QuikClot EMS 4x4 Dressing w/X-ray EUDAMED
Quikclot GUDID
Generic name
Non-organic haemostatic agent
Device name
Qc Ems 4X4IN Dressing W/ X-Ray, 10X
Model / Ref / Catalog
IPN928798, 636
Primary DI / UDI-DI
10841495150361
Basic UDI-DI
B-10841495150361
510(k) Number
FDA product code
FRO
EMDN code
M040504 Inorganic haemostatic devices
GMDN term
Non-organic haemostatic agent
Device class
Class III EUDAMED
U GUDID
EU registration type
Legacy device (under a directive)
EU market of registration
Ireland
GUDID distribution status
In Commercial Distribution
MRI safety
MR Safe

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class III
GUDID
U

Device class is stated on each registry's own scale: Class III in the EU (EUDAMED), U in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under INORGANIC HAEMOSTATIC DEVICES.

Other devices from Teleflex Incorporated

  • Arrow IPNB00820 Open recall

    Class II
  • Arrow IPNB00826 Open recall

    Class II
  • Arrow IPNB00822 Open recall

    Class II
  • Arrow IPNB00827 Open recall

    Class II

See all devices from Teleflex Incorporated →

Properties

  • Supplied sterile
  • Single use
  • Incorporates a medicinal substance
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (19, all answered No)