# QWIX Positioning Screw

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/qwix-positioning-screw-hwc>
- Manufacturer: [Newdeal Sas](https://devicerts.com/manufacturers/newdeal-sas) (FDA registration: United States)
- Name in the registry: QWIX POSITIONING SCREW
- Device class: Class II (US FDA)
- FDA product code: HWC

## Overview

*AI-generated summary, 2026-09-19. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The QWIX Positioning Screw is a cannulated, fully threaded, self-tapping orthopedic fixation device designed for bone stabilization. It is classified as a bone screw (HWC) and manufactured from titanium alloy (Ti-6Al-4V ELI) to ensure biocompatibility and strength for surgical applications.

This device is used in orthopedic procedures for bone fragment fixation, osteotomies, and arthrodesis in the hand, foot, or ankle. Available in diameters of 5.5 mm and 7.5 mm with lengths ranging from 30 mm to 120 mm, it is supplied sterile and intended for single-use. The QWIX Positioning Screw holds FDA 510(k) clearance (K071639) under the Special 510(k) review pathway for orthopedic devices.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K071639 · decision 2007-07-09 · decision SESE · status: Active

## Recalls

- Z-2600-2016 · Class II · terminated · initiated 2016-07-21: Labeling on the Qwix Screw product states that it is a "compression screw" instead of a "positioning screw".

## Identifiers

- 510(k) Number: K071639 [FDA 510(k)]
- FDA product code: HWC [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 888.3040 [FDA 510(k)]
- Advisory committee: Orthopedic [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: QWIX Positioning Screw, Newdeal Sas. deviCERTS medical device catalogue. https://devicerts.com/devices/qwix-positioning-screw-hwc (data as of 2026-11-22).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-22
- JSON: <https://devicerts.com/devices/qwix-positioning-screw-hwc.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/qwix-positioning-screw-hwc
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.
