Skip to content

R-20J 563-55050-60

by Shimadzu Corporation

Ref 563-55050-60

R-20J 563-55050-60 is a medical device (EU MDD Class IIb; FDA Class II; FDA product code IZX, Collimator, Manual, Radiographic; EMDN category radiology instruments - hardware accessories) made by Shimadzu Corporation, registered in EUDAMED on 14 Mar 2023 (Basic UDI-DI B-04540217062416), cleared under FDA 510(k) K101036 on 26 Aug 2010 and listed in FDA GUDID since 21 Feb 2020 (UDI-DI 04540217062416), active as of 12 Nov 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

1 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K101036

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 12 Nov 2026.

Regulatory status

as of registry sync 12 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-04540217062416 Basic UDI-DI 04540217062416UDI-DIDate14 Mar 2023RegisteredStatusActive
United StatesGUDID listing GUDID Number04540217062416 UDI-DI Date21 Feb 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Abbreviated NumberK101036 Date26 Aug 2010DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 12 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-04540217062416 registered 14 Mar 2023 Active
  • FDA 510(k) K101036 decided 26 Aug 2010 Active
  • FDA GUDID UDI-DI 04540217062416 listed 21 Feb 2020 Listed

Recalls

1 recall · FDA

    • Terminated Z-0261-2013 FDA Class II initiated 28 Oct 2011

    Shimadzu is recalling Diagnostic X-ray Beam-Limiting Device, Mobile x-ray system and Diagnostic x-ray tube assembly because they do not comply with the Product Performance Standards, 21CFR 1020.30 (m) Beam quality --(1) Half-value layer (HVL), which was revised in 2006. Certain devices might not comply with the requirements for them in some x-ray generating condition after the revision in 2006.

Timeline

4 dated events

  1. Cleared FDA 510(k) K101036
  2. Recall initiated FDA recalls Z-0261-2013
  3. Listed FDA GUDID 04540217062416
  4. Registered EUDAMED B-04540217062416

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
R-20J
Generic name
Manual-aperture-control diagnostic x-ray system collimator, non-motorized
Device name
Collimator Type R-20J
Model / reference
563-55050-60
Primary DI / UDI-DI
04540217062416
Basic UDI-DI
B-04540217062416
510(k) Number
FDA product code
IZX
EMDN code
Z11030580 Radiology instruments - hardware accessories
GMDN term
Manual-aperture-control diagnostic x-ray system collimator, non-motorized
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
892.1610
EU registration type
Legacy device (under a directive)
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under RADIOLOGY INSTRUMENTS - HARDWARE ACCESSORIES.

Other devices from Shimadzu Corporation

See all devices from Shimadzu Corporation →

Properties

  • Serial number
  • Manufacturing date
Other properties (21, all answered No)