# Radial Immuno-Test for Human C-Reactive Protein

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/radial-immuno-test-for-human-c-reacti-dck>
- Manufacturer: [Kent Laboratories, Inc.](https://devicerts.com/manufacturers/fda-fei-3019906) (FDA registration: United States)
- Name in the registry: RADIAL IMMUNO-TEST FOR HUMAN C-REACTI
- Device class: Class II (US FDA)
- FDA product code: DCK

## Overview

*AI-generated summary, 2026-10-01. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

This device is a C-Reactive Protein, Antigen, Antiserum, and Control as classified under FDA regulation 866.5270. It functions as an immunodiffusion assay designed to qualitatively detect human C-reactive protein (CRP) in serum or plasma, a marker used in clinical immunology for assessing inflammation or infection. The test relies on radial immunodiffusion principles, where antigen-antibody interactions form visible precipitation lines proportional to CRP concentration.

The Radial Immuno-Test for Human C-Reactive Protein is supplied as a kit for in vitro diagnostic use in clinical laboratories. It is intended for single-use and requires no special handling beyond standard laboratory procedures. The device received FDA 510(k) clearance (K831958) under the Traditional pathway, with a decision of Substantially Equivalent (SESE) in 1983. No MRI safety or sterility specifications are noted in the regulatory data, and the product is classified as a Class II device under FDA guidelines.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K831958 · decision 1983-07-19 · decision SESE · status: Active

## Recalls

No recall on record.

## Identifiers

- 510(k) Number: K831958 [FDA 510(k)]
- FDA product code: DCK [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 866.5270 [FDA 510(k)]
- Advisory committee: Immunology [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: Radial Immuno-Test for Human C-Reactive Protein, Kent Laboratories, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/radial-immuno-test-for-human-c-reacti-dck (data as of 2026-11-22).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-22
- JSON: <https://devicerts.com/devices/radial-immuno-test-for-human-c-reacti-dck.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/radial-immuno-test-for-human-c-reacti-dck
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.