Skip to content

KM002

by KH Medical Co., Ltd.

Ref KM002Model RADICHAMP

KM002 is an in vitro diagnostic device (EU IVDR Class A; FDA Class II; FDA product code OOI, Real Time Nucleic Acid Amplification System) made by KH Medical Co., Ltd., registered in EUDAMED on 16 Sep 2022 (Basic UDI-DI 88002043RADICHAMP25) and listed in FDA GUDID since 19 Sep 2022 (UDI-DI 08800204300096), active as of 22 Oct 2026.

Active European Union. Also listed in GUDID (US).

CE IVDR

Valid until

No date given

EUDAMED holds no validity date

FDA recalls

Not checked

No FDA submission to match recalls against

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing GUDID Number08800204300096 UDI-DI Date19 Sep 2022ListedStatusListed GUDID: in commercial distribution
European UnionCE/IVDR EUDAMED Number88002043RADICHAMP25 Basic UDI-DI 08800204300096UDI-DIDate16 Sep 2022RegisteredStatusActive

Official records

From the FDA record

Device description
The RADI CHAMP260 is a stand-alone automated isothermal amplification and detection system for target nucleic acid sequences found in human specimens. The instrument is used in conjunction with KH Medical’s LOOP-Mediated Amplification in vitro diagnostic products. RADI CHAMP260 is designed to freely manipulate specific temperature and running time for amplification of samples by 7 inch touch screen. Amplification of target DNA occurs during the heat cycle and results in the formation of precipitate detected by the RADI CHAMP260 optics system. The precipitate generated by the presence of amplified target DNA leads to a turbid Sample/Control reaction solution which is then measured by absorbance. The RADI CHAMP260 uses the change in turbidity of each Sample/Control reaction solution to report assay results as INVALID, POSITIVE, or NEGATIVE on the 7 inch touch screen.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

2 registries list this device

  • EUDAMED Basic UDI-DI 88002043RADICHAMP25 registered 16 Sep 2022 Active
  • FDA GUDID UDI-DI 08800204300096 listed 19 Sep 2022 Listed

Timeline

2 dated events

  1. Registered EUDAMED 88002043RADICHAMP25
  2. Listed FDA GUDID 08800204300096

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDR Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Trade name
Radi CHAMP260
Generic name
Thermal cycler nucleic acid amplification analyser IVD, laboratory
Model / reference
RADICHAMP, KM002
Primary DI / UDI-DI
08800204300096
Basic UDI-DI
88002043RADICHAMP25
FDA product code
OOI
EMDN code
W02050116 Nucleic acid testing integrated extraction /amplification /detection systems
GMDN term
Thermal cycler nucleic acid amplification analyser IVD, laboratory
Device class
Class A EUDAMED
Class II GUDID
Regulation number
862.2570
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class A
GUDID
Class II

Device class is stated on each registry's own scale: Class A in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
KR-MF-000017883
Authorised representative
Medical Technology Promedt Consulting GmbH DE-AR-000000085

Similar devices in this category

Other devices filed under NUCLEIC ACID TESTING INTEGRATED EXTRACTION /AMPLIFICATION /DETECTION SYSTEMS.

Other devices from KH Medical Co., Ltd.

See all devices from KH Medical Co., Ltd. →

Properties

  • Professional testing
  • IVD instrument
  • Premarket exempt
  • Lot / batch number
Other properties (22, all answered No)