Skip to content

RapidSorb 805.603.10S

by Synthes GmbH

RapidSorb 805.603.10S (80560310S) is a craniofacial bone screw (FDA Class II; FDA product code JEY, Plate, Bone) made by Synthes GmbH, cleared under FDA 510(k) K062789 on 27 Feb 2007 (1 earlier submission) and listed in FDA GUDID since 14 Sep 2015 (UDI-DI 20887587061631), active as of 12 Nov 2026. 3 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

3 closed

Documents

Trust

Unverified

Source GUDID, synced 12 Nov 2026.

Regulatory status

as of registry sync 12 Nov 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number20887587061631 UDI-DI Date14 Sep 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK062789 Date27 Feb 2007DecidedStatusActive

Official records

From the FDA record

Device description
1.5MM RAPID RESORBABLE CORTEX SCREW 3MM-STERILE
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 12 Nov 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K062789 decided 27 Feb 2007 Active· +1 more in the status table
  • FDA GUDID UDI-DI 20887587061631 listed 14 Sep 2015 Listed

Recalls

3 recalls · FDA

  • 3 recalls, same reason

    • Terminated Z-1919-2016 FDA Class II initiated 2 May 2016
    • Terminated Z-1920-2016 FDA Class II initiated 2 May 2016
    • Terminated Z-1918-2016 FDA Class II initiated 2 May 2016

    Labeling errors. The outer packge label expiration date may exceed the expiration date of the subcomponents.

Timeline

6 dated events

  1. Cleared FDA 510(k) K030069
  2. Cleared FDA 510(k) K062789
  3. Listed FDA GUDID 20887587061631
  4. Recall initiated FDA recalls Z-1919-2016
  5. Recall initiated FDA recalls Z-1920-2016
  6. Recall initiated FDA recalls Z-1918-2016

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
RapidSorb
Generic name
Craniofacial bone screw, bioabsorbable
Model / Ref / Catalog
805.603.10S, 80560310S
Primary DI / UDI-DI
20887587061631
510(k) Number
FDA product code
JEY
GMDN term
Craniofacial bone screw, bioabsorbable
Device class
Class II
Regulation number
872.4760
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code JEY (PLATE, BONE).

Other devices from Synthes GmbH

  • Tomofix

    Class IIb
  • 03.111.100S

    Class IIb
  • 68.134.011

    Class II
  • Volt 68.134.111

    Class II

See all devices from Synthes GmbH →

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (9, all answered No)