# RayStation 10.1

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/raystation-10-1-muj>
- Manufacturer: [RaySearch Laboratories AB (PUBL)](https://devicerts.com/manufacturers/raysearch-laboratories-ab-publ) (Sweden)
- Device class: Class II (US FDA)
- FDA product code: MUJ

## Overview

*AI-generated summary, 2026-10-01. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

RayStation 10.1 is a Radiation Therapy Treatment Planning System designed for advanced radiotherapy planning. It integrates multi-criteria optimization and adaptive therapy capabilities to support external beam therapy, brachytherapy, and particle therapy (including protons, helium, and carbon ions). The system facilitates precise dose calculations and treatment planning across diverse radiation modalities, enhancing treatment accuracy and customization for complex cases.

This software-based system is intended for use in radiology departments and oncology centers, where it aids clinicians in generating optimized treatment plans. Supplied as a standalone software solution, it requires compatible hardware and network infrastructure for operation. The device holds FDA 510(k) clearance (K210645) under the Radiology advisory committee, classified as a Class II medical device under regulation 892.5050. No sterility or single-use requirements apply, as it is a reusable digital platform.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K210645 · decision 2021-06-29 · decision SESE · status: Active

## Recalls

- Z-1102-2026 · Class II · ongoing · initiated 2025-11-28: Potential for the invalidation for calculated radiation dose does not work as intended for certain Regions of Interest (ROIs). This issue occurs for some ROI(s) which have no contours and either have a material override defined, or are of type Bolus, Fixation, or Support. In these cases, adding geometry to the ROI, subsequently modifying geometry, or removing the material override does not invalidate dose as intended.
- Z-2490-2025 · Class II · ongoing · initiated 2025-08-08: DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray's iDMS, are not guaranteed to be unique.
- Z-1188-2025 · Class II · ongoing · initiated 2025-01-16: Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in RayStation version 4.5 to 2024B including some service packs.
- Z-1747-2024 · Class II · ongoing · initiated 2024-03-28: Potential for reported SSD to be too high.
- Z-1482-2024 · Class II · ongoing · initiated 2024-02-23: A use error that has occurred with RayStation/RayPlan, where material override using Silicon, Si, was incorrectly selected for a silicone gel polymer implant.
- Z-0848-2022 · Class II · terminated · initiated 2021-09-09: If the dynamic jaw mode is used and an optimization is continued after changing the dose grid or modifying the target ROI, the positions of the jaws may change unexpectedly for some control points. User must be aware to avoid unnecessary jaw openings during treatment planning

## Identifiers

- 510(k) Number: K210645 [FDA 510(k)]
- FDA product code: MUJ [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 892.5050 [FDA 510(k)]
- Advisory committee: Radiology [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: RayStation 10.1, RaySearch Laboratories AB (PUBL). deviCERTS medical device catalogue. https://devicerts.com/devices/raystation-10-1-muj (data as of 2026-11-20).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-20
- JSON: <https://devicerts.com/devices/raystation-10-1-muj.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/raystation-10-1-muj
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.
