RayStation 11.0.1
by RaySearch Laboratories AB (PUBL)
RayStation 11.0.1 is a Class II device made by RaySearch Laboratories AB (PUBL), cleared under FDA 510(k) K211867 on 8 Sep 2021 and listed in FDA GUDID since 30 Sep 2021 (UDI-DI 07350002010433), active as of 23 Oct 2026. 8 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
8 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number07350002010433 | Date30 Sep 2021 | StatusListed |
| United States | FDA 510(k)SESE | NumberK211867 | Date8 Sep 2021 | StatusActive |
Official records
- AccessGUDID record 07350002010433
- FDA 510(k) database K211867
Across registries
- FDA 510(k) K211867 decided 8 Sep 2021 Active
- FDA GUDID UDI-DI 07350002010433 listed 30 Sep 2021 Listed
Recalls
-
- Ongoing Z-1103-2026
Potential for the invalidation for calculated radiation dose does not work as intended for certain Regions of Interest (ROIs). This issue occurs for some ROI(s) which have no contours and either have a material override defined, or are of type Bolus, Fixation, or Support. In these cases, adding geometry to the ROI, subsequently modifying geometry, or removing the material override does not invalidate dose as intended.
-
- Ongoing Z-2491-2025
DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray's iDMS, are not guaranteed to be unique.
-
- Ongoing Z-1189-2025
Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in RayStation version 4.5 to 2024B including some service packs.
-
- Ongoing Z-1748-2024
Potential for reported SSD to be too high.
-
- Ongoing Z-1482-2024
A use error that has occurred with RayStation/RayPlan, where material override using Silicon, Si, was incorrectly selected for a silicone gel polymer implant.
-
- Ongoing Z-0850-2022
Incorrect source to skin or surface distance (SSD) calculation may result in dose error when using RayStation system.
-
- Ongoing Z-0732-2022
If a new primary image set is selected while the cine loop is running, the primary image set will be displayed as both primary and secondary image set in all side-by-side views. This will also be true for any new patient or case opened while the cine loop is running
-
- Ongoing Z-0849-2022
An issue where the combined density in a dose grid voxel partially covered by the External ROI and also partially covered by an ROI of type Bolus, Support or Fixation may be unexpected.The density in the voxel can be both under- and overestimated
Timeline
- Cleared FDA 510(k) K211867
- Recall initiated FDA recalls Z-0849-2022
- Listed FDA GUDID 07350002010433
- Recall initiated FDA recalls Z-0732-2022
- Recall initiated FDA recalls Z-0850-2022
- Recall initiated FDA recalls Z-1482-2024
- Recall initiated FDA recalls Z-1748-2024
- Recall initiated FDA recalls Z-1189-2025
- Recall initiated FDA recalls Z-2491-2025
- Recall initiated FDA recalls Z-1103-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- RayStation
- Generic name
- Radiation therapy software
- Model / reference
- 11.0.1
- Primary DI / UDI-DI
- 07350002010433
- 510(k) Number
- FDA product code
- MUJ
- GMDN term
- Radiation therapy software
- Device class
- Class II
- Regulation number
- 892.5050
- GUDID distribution status
- In Commercial Distribution
Similar devices in this category
Other devices filed under Radiation therapy software.
- FilmQA Pro 8.0 987957 by Ashland Specialty Ingredients, G.P.
- Standard Imaging QA Pilot 91348 by STANDARD IMAGING INC.
- Vitesse 5.0 by Varian Medical Systems, Inc.
- FilmQA Pro 7.0 N/A by Ashland Specialty Ingredients, G.P.
- VERIQA software S070031 by PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH
- ART-Plan v.1.10.0 by Therapanacea Sas
- Standard Imaging IMSure QA Software v3 91326 by STANDARD IMAGING INC.