RayStation 12A SP2
by RaySearch Laboratories AB (PUBL)
Part of a family of 11 devices: see the family page
Ref 13.1
RayStation 12A SP2 is a radiation therapy software (EU MDR Class IIb; FDA Class II; FDA product code MUJ, System, Planning, Radiation Therapy Treatment) made by RaySearch Laboratories AB (PUBL), registered in EUDAMED on 4 Aug 2026 (Basic UDI-DI 73500020101H8) with CE/MDR certificate 28620117938-05 valid until 27 Sep 2031, cleared under FDA 510(k) K222312 on 29 Mar 2023 and listed in FDA GUDID since 18 Oct 2023 (UDI-DI 07350002010730), active as of 7 Nov 2026. 6 FDA recalls are linked to it.
Active
Valid until
27 Sep 2031
FDA recalls
6 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number28620117938-05 | Date28 Sep 2026 | StatusActive |
| United States | GUDID listing GUDID | Number07350002010730 | Date18 Oct 2023 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK222312 | Date29 Mar 2023 | StatusActive |
Official records
- EUDAMED public site 73500020101H8
- AccessGUDID record 07350002010730
- AccessGUDID record 07350002010679
- FDA 510(k) database K222312
Across registries
- EUDAMED Basic UDI-DI 73500020101H8 registered 4 Aug 2026 Active
- FDA 510(k) K222312 decided 29 Mar 2023 Active
- FDA GUDID UDI-DI 07350002010730 listed 18 Oct 2023 Listed
Certificates
- 28620117938-05 Active
Quality management system EU MDR
- Certifier
- Intertek Medical Notified Body AB 2862
- Issued
- 28 Sep 2026
- Expires
- 27 Sep 2031
- Reason
- Add device or group
Recalls
-
- Ongoing Z-1105-2026
Potential for the invalidation for calculated radiation dose does not work as intended for certain Regions of Interest (ROIs). This issue occurs for some ROI(s) which have no contours and either have a material override defined, or are of type Bolus, Fixation, or Support. In these cases, adding geometry to the ROI, subsequently modifying geometry, or removing the material override does not invalidate dose as intended.
-
- Ongoing Z-2493-2025
DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray's iDMS, are not guaranteed to be unique.
-
- Ongoing Z-1191-2025
Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in RayStation version 4.5 to 2024B including some service packs.
-
- Ongoing Z-1750-2024
- Ongoing Z-1751-2024
Potential for reported SSD to be too high.
-
- Ongoing Z-1482-2024
A use error that has occurred with RayStation/RayPlan, where material override using Silicon, Si, was incorrectly selected for a silicone gel polymer implant.
Timeline
- Listed FDA GUDID 07350002010730
- Recall initiated FDA recalls Z-1482-2024
- Recall initiated FDA recalls Z-1750-2024
- Recall initiated FDA recalls Z-1751-2024
- Recall initiated FDA recalls Z-1191-2025
- Recall initiated FDA recalls Z-2493-2025
- Recall initiated FDA recalls Z-1105-2026
- Registered EUDAMED 73500020101H8
- Certificate issued EUDAMED 28620117938-05
- Certificate expires EUDAMED 28620117938-05
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- RayStation 12A SP1 EUDAMEDRayStation 12A SP2 EUDAMEDRayStation GUDID
- Generic name
- Radiation therapy software
- Model / reference
- 13.1 EUDAMED12A SP2 GUDID12A SP1 GUDID
- Primary DI / UDI-DI
- 07350002010730, 07350002010679
- Basic UDI-DI
- 73500020101H8
- Direct marketing DI
- 0735000201067907350002010730
- 510(k) Number
- FDA product code
- MUJ
- EMDN code
- Z11019082 Various radiotherapy and radiosurgery instruments - software accessories
- GMDN term
- Radiation therapy software
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 892.5050
- Special device type
- Software
- EU registration type
- Standard device
- EU market of registration
- Austria
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 13.1 | 12A SP2 12A SP1 |
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under VARIOUS RADIOTHERAPY AND RADIOSURGERY INSTRUMENTS.
- Standard Imaging TomoScanner 91750 by STANDARD IMAGING INC.
- Standard Imaging MAX 4000 Plus Electrometer 90020 by STANDARD IMAGING INC.
- Proton Therapy Combined System IBA-PTC-00 by Ion Beam Applications S.A.
- Gating Module 4D -CT - Siemens Somatom SDX0361N by DYN'R
- Real Time Coach Mk3 5056190501297 by Vision RT Ltd.
- Xstrahl 150 X-Ray System - Ceiling by Xstrahl, Ltd.
- DoseRT camera-computer interface box by Vision RT Ltd.
- Xstrahl 300 X-Ray System - Floor by Xstrahl, Ltd.
- Sensus Healthcare Superficial X-Ray Radiation Therapy System with Ultrasonic Imaging by Sensus Healthcare
- Cranial 4PI CT Overlay 43420A by Brainlab SE