RayStation 5.0.3
by RaySearch Laboratories AB (PUBL)
RayStation 5.0.3, a radiation therapy software (FDA Class II; FDA product code MUJ, System,Planning,Radiation Therapy Treatment) made by RaySearch Laboratories AB (PUBL), was cleared under FDA 510(k) K160093 on 8 Apr 2016 and listed in FDA GUDID on 11 Jul 2017 (UDI-DI 07350002010020); the registry lists it as not in commercial distribution (GUDID) as of 23 Oct 2026. FDA recalls on record: 7.
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number07350002010020 | Date11 Jul 2017 | StatusListed |
| United States | FDA 510(k)SESE | NumberK160093 | Date8 Apr 2016 | StatusActive |
Official records
- AccessGUDID record 07350002010020
- FDA 510(k) database K160093
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K160093 decided 8 Apr 2016 Active
- FDA GUDID UDI-DI 07350002010020 listed 11 Jul 2017 Listed
Recalls
-
- Ongoing Z-1194-2025
Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in RayStation version 4.5 to 2024B including some service packs.
-
- Terminated Z-1815-2017
An error in NVIDIA GPU (Graphics Processing Unit) card drivers can occur for certain software programs. In a non-standard Citrix environment where the GPU settings are configured with a virtual Citrix graphics board (graphics card) an erroneous calculation may be allowed.
-
- Terminated Z-0721-2017
Software anomaly; an issue was found with the proton Pencil Beam Scanning (PBS) dose calculation in RayStation 4.0, 4.5, 4.7 and 5.0. For treatment plans with a combination of range shifter, large air gap and beams that enter the patient surface at an oblique angle, the dose calculation accuracy may be less than expected.
-
- Terminated Z-0720-2017
An error may occur with the display of dose computed on images other than the planning CT (auxiliary CT) when using multiple patient cases in RayStation 5. If a CT image set with the same Frame of Reference as the displayed auxiliary CT set exists in another case, the dose display may be incorrect. When the error occurs, the display of dose in patient views, including the maximum dose position, the dynamic isodose lines and the dose grid may be incorrect. The dose value normally displayed in the upper left corner when pointing in the 2D view may be incorrect or missing.
-
- Terminated Z-0038-2017
RaySearch became aware of the problem as it was discovered in cooperation with a customer experimenting with the dose calculation on a phantom. The correction concerns two issues found with the dose calculation when using a region of interest (ROI) of type Fixation or Support with material override within the patient outline (External ROI) in RayStation 2.5, 3.0, 3.5, 4.0, 4.5, 4.7, 5.0 and 4.3 (InverseArc 1.0).
-
- Terminated Z-2206-2016
An issue was found with the evaluation of biological clinical goals in RayStation 3.0, RayStation 3.5, RayStation 4.0, RayStation 4.5, RayStation 4.7 and RayStation 5. Biological clinical goals for an adapted plan based on another planning CT than the original planning CT will show incorrect values. -- To the best of the firm's knowledge, the issue has not caused any patient mistreatment or other incidents. However, the user must be aware of the following information to avoid incorrect plan evaluation during treatment planning.
-
- Terminated Z-0079-2017
For a treatment plan consisting of multiple beam sets, the table for ROI plan dose statistics in the report may show the statistics for a beam set dose. The error can only be triggered when using a report template where statistics for a beam set dose is included as the last dose statistics prior to the plan dose statistics.
Timeline
- Cleared FDA 510(k) K160093
- Recall initiated FDA recalls Z-0079-2017
- Recall initiated FDA recalls Z-2206-2016
- Recall initiated FDA recalls Z-0038-2017
- Recall initiated FDA recalls Z-0720-2017
- Recall initiated FDA recalls Z-0721-2017
- Recall initiated FDA recalls Z-1815-2017
- Listed FDA GUDID 07350002010020
- Recall initiated FDA recalls Z-1194-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- RayStation
- Generic name
- Radiation therapy software
- Model / reference
- 5.0.3
- Primary DI / UDI-DI
- 07350002010020
- FDA product code
- MUJ
- GMDN term
- Radiation therapy software
- Device class
- Class II
- Regulation number
- 892.5050
- GUDID distribution status
- Not in Commercial Distribution
Similar devices in this category
Other devices filed under Radiation therapy software.
- Standard Imaging Adaptivo v1 91350 by STANDARD IMAGING INC.
- FilmQA Pro 8.0 987957 by Ashland Specialty Ingredients, G.P.
- Vitesse 5.0 by Varian Medical Systems, Inc.
- FilmQA Pro 7.0 N/A by Ashland Specialty Ingredients, G.P.
- VERIQA software S070031 by PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH
- ART-Plan v.1.10.0 by Therapanacea Sas