RayStation 6.1
by RaySearch Laboratories AB (PUBL)
RayStation 6.1 is a radiation therapy software (FDA Class II; FDA product code MUJ, System,Planning,Radiation Therapy Treatment) made by RaySearch Laboratories AB (PUBL), cleared under FDA 510(k) K171536 on 27 Jun 2017 and listed in FDA GUDID since 13 Jul 2017 (UDI-DI 07350002010037), active as of 23 Oct 2026. 6 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
2 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number07350002010037 | Date13 Jul 2017 | StatusListed |
| United States | FDA 510(k)SESE | NumberK171536 | Date27 Jun 2017 | StatusActive |
Official records
- AccessGUDID record 07350002010037
- FDA 510(k) database K171536
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K171536 decided 27 Jun 2017 Active
- FDA GUDID UDI-DI 07350002010037 listed 13 Jul 2017 Listed
Recalls
-
- Ongoing Z-2494-2025
DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray's iDMS, are not guaranteed to be unique.
-
- Ongoing Z-1192-2025
Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in RayStation version 4.5 to 2024B including some service packs.
-
- Terminated Z-2290-2018
The dose calculation accuracy may in some situations be less than expected. The user must be aware in order to avoid incorrect dose calculations during treatment planning.
-
- Terminated Z-1275-2018
Software issue with Center Beam in Field functionality. Issue can result in incorrect treatment volume delivered to patient.
-
- Terminated Z-1930-2019
When calculating electron Monte Carlo dose with a very large number of histories, the dose calculation may be wrong
-
- Terminated Z-0380-2018
For the proton QA preparation module in RayStation 6 (including SP1 and SP2), if the snout position or gap is modified in the QA module, the dose in the QA module may be computed for a different setup than what is used for QA measurements. This could result in an incorrect dosage being provided to a patient.
Timeline
- Cleared FDA 510(k) K171536
- Listed FDA GUDID 07350002010037
- Recall initiated FDA recalls Z-0380-2018
- Recall initiated FDA recalls Z-1930-2019
- Recall initiated FDA recalls Z-1275-2018
- Recall initiated FDA recalls Z-2290-2018
- Recall initiated FDA recalls Z-1192-2025
- Recall initiated FDA recalls Z-2494-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- RayStation
- Generic name
- Radiation therapy software
- Model / reference
- 6.1
- Primary DI / UDI-DI
- 07350002010037
- 510(k) Number
- FDA product code
- MUJ
- GMDN term
- Radiation therapy software
- Device class
- Class II
- Regulation number
- 892.5050
- GUDID distribution status
- In Commercial Distribution
Similar devices in this category
Other devices filed under Radiation therapy software.
- Standard Imaging Adaptivo v1 91350 by STANDARD IMAGING INC.
- FilmQA Pro 8.0 987957 by Ashland Specialty Ingredients, G.P.
- Vitesse 5.0 by Varian Medical Systems, Inc.
- FilmQA Pro 7.0 N/A by Ashland Specialty Ingredients, G.P.
- VERIQA software S070031 by PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH
- ART-Plan v.1.10.0 by Therapanacea Sas