REAADS Anti-Phosphatidylserine IgG/IgM Semi-Quantitative Test Kit (96 Well)

FDA UDI

Class II (US FDA UDI)

by Corgenix Medical Corporation

Identity

Trade Name
REAADS Anti-Phosphatidylserine IgG/IgM Semi-Quantitative Test Kit (96 Well) FDA UDI
Generic Name
Phosphatidylserine antibody IVD, kit, enzyme immunoassay (EIA) FDA UDI
Device Name
INTENDED USE Detection and semi-quantitation of anti-phosphatidylserine antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Diagnostic Use. SUMMARY AND EXPLANATION OF THE ANTI-PHOSPHATIDYLSERINE TEST High serum levels of anti-phospholipid antibodies are frequently detected in patients with autoimmune (i.e., SLE) and non-autoimmune diseases, as well as in apparently healthy individuals. These antibodies have been associated with an increased risk for recurrent arterial and venous thrombotic events, thrombocytopenia and fetal loss. Phosphatidylserine is a more physiologically relevant phospholipid due to its presence in cell membranes of endothelial cells and platelets. PRINCIPLE OF THE TEST The test is an indirect ELISA. Diluted serum/plasma samples, calibrator sera, and controls are incubated in phosphatidylserine coated microwells. β2-glycoprotein I is provided in the sample diluent. After the removal of unbound serum/plasma proteins by washing, antibodies specific for human IgG or IgM, labeled with horseradish peroxidase (HRP), are added forming complexes with the phosphatidylserine bound antibodies. Two enzyme-conjugated antibody solutions are provided, one specific for human IgG antibodies and one specific for human IgM antibodies. Following another washing step, the bound enzyme-antibody conjugate is assayed by the addition of a single solution containing tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of anti-phosphatidylserine (aPS) antibodies. Results are obtained by reading the O.D. of each well in a spectrophotometer. Calibrator sera are provided for both IgG and IgM antibody concentrations expressed in GPS or MPS units. Control and patient results are determined from the calibration curve. Refer to Package Insert. FDA UDI
Model / Reference
030-001 FDA UDI
Description
INTENDED USE Detection and semi-quantitation of anti-phosphatidylserine antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Diagnostic Use. SUMMARY AND EXPLANATION OF THE ANTI-PHOSPHATIDYLSERINE TEST High serum levels of anti-phospholipid antibodies are frequently detected in patients with autoimmune (i.e., SLE) and non-autoimmune diseases, as well as in apparently healthy individuals. These antibodies have been associated with an increased risk for recurrent arterial and venous thrombotic events, thrombocytopenia and fetal loss. Phosphatidylserine is a more physiologically relevant phospholipid due to its presence in cell membranes of endothelial cells and platelets. PRINCIPLE OF THE TEST The test is an indirect ELISA. Diluted serum/plasma samples, calibrator sera, and controls are incubated in phosphatidylserine coated microwells. β2-glycoprotein I is provided in the sample diluent. After the removal of unbound serum/plasma proteins by washing, antibodies specific for human IgG or IgM, labeled with horseradish peroxidase (HRP), are added forming complexes with the phosphatidylserine bound antibodies. Two enzyme-conjugated antibody solutions are provided, one specific for human IgG antibodies and one specific for human IgM antibodies. Following another washing step, the bound enzyme-antibody conjugate is assayed by the addition of a single solution containing tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of anti-phosphatidylserine (aPS) antibodies. Results are obtained by reading the O.D. of each well in a spectrophotometer. Calibrator sera are provided for both IgG and IgM antibody concentrations expressed in GPS or MPS units. Control and patient results are determined from the calibration curve. Refer to Package Insert. FDA UDI

Identifiers

Catalog Number
030-001 FDA UDI
Primary DI / UDI-DI
00855360006090 FDA UDI
FDA Product Code
MID FDA UDI
GMDN Term
Phosphatidylserine antibody IVD, kit, enzyme immunoassay (EIA) FDA UDI

Classification

Device Class
Class II FDA UDI
Regulation Number
866.5660 FDA UDI
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

No

FDA UDI

Single Use

Yes

FDA UDI

Implantable

No

FDA UDI

Contains Latex

No

FDA UDI

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

Yes

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

Yes

FDA UDI

Serial Number

No

FDA UDI

Expiration Date

Yes

FDA UDI

Manufacturing Date

No

FDA UDI

Category: Phosphatidylserine antibody IVD, kit, enzyme immunoassay (EIA)

REAADS Anti-Phosphatidylserine IgG/IgM Semi-Quantitative Test Kit (96 Well) by Corgenix Medical Corporation — Class II — FDA UDI — listed in FDA GUDID

Similar devices

Also classified as Phosphatidylserine antibody IVD, kit, enzyme immunoassay (EIA).

Authorization Coverage (1 country)

Regulatory Authorizations

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Sources (1)

  • FDA UDI 31c6b868-dda8-4d60-baa2-4d24b192982a 36 fields · synced Jun 8, 2026