← Back to catalogue

REAADS IgA Anti-Cardiolipin Semi-Quantitative Test Kit (96-Well)

FDA UDI

Class II (US FDA UDI)

by Corgenix Medical Corporation

Identity

Trade Name
REAADS IgA Anti-Cardiolipin Semi-Quantitative Test Kit (96-Well) FDA UDI
Generic Name
Anticardiolipin antibody IVD, kit, enzyme immunoassay (EIA) FDA UDI
Device Name
INTENDED USE For the detection and semi-quantitation of anti-cardiolipin antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Diagnostic Use. SUMMARY AND EXPLANATION OF THE IGA TEST Anti-phospholipid antibodies are autoantibodies that react with most negatively charged phospholipids, including cardiolipin (CL). Anti-cardiolipin (aCL) antibodies are frequently found in patients with systemic lupus erythematosus (SLE). Elevated levels of aCL antibodies have been reported to be significantly associated with the presence of both venous and arterial thrombosis, thrombocytopenia, and recurrent fetal loss. The term “anti-phospholipid syndrome” (APS) has been introduced to describe patients who present these clinical manifestations. PRINCIPLE OF THE TEST The test is an indirect ELISA. Diluted serum samples, calibrator sera, and controls are incubated in cardiolipin coated microwells, allowing aCL antibodies present in the samples to react with the immobilized antigen. After removal of unbound serum proteins by washing, antibodies specific for human IgA labeled with horseradish peroxidase (HRP) are added forming complexes with the cardiolipin bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of IgA aCL antibodies. Results are obtained by reading the O.D. of each well with a spectrophotometer. Calibrator sera are provided, with the IgA aCL concentration expressed in APL units. The O.D. values of the controls and patient samples are multiplied by the conversion factor to obtain IgA aCL values, expressed in APL units. Control and patient results are determined from the calibration curve. Refer to Package Insert. FDA UDI
Model / Reference
026-001 FDA UDI
Description
INTENDED USE For the detection and semi-quantitation of anti-cardiolipin antibodies in individuals with systemic lupus erythematosus (SLE) and lupus-like disorders (anti-phospholipid syndrome). For In Vitro Diagnostic Use. SUMMARY AND EXPLANATION OF THE IGA TEST Anti-phospholipid antibodies are autoantibodies that react with most negatively charged phospholipids, including cardiolipin (CL). Anti-cardiolipin (aCL) antibodies are frequently found in patients with systemic lupus erythematosus (SLE). Elevated levels of aCL antibodies have been reported to be significantly associated with the presence of both venous and arterial thrombosis, thrombocytopenia, and recurrent fetal loss. The term “anti-phospholipid syndrome” (APS) has been introduced to describe patients who present these clinical manifestations. PRINCIPLE OF THE TEST The test is an indirect ELISA. Diluted serum samples, calibrator sera, and controls are incubated in cardiolipin coated microwells, allowing aCL antibodies present in the samples to react with the immobilized antigen. After removal of unbound serum proteins by washing, antibodies specific for human IgA labeled with horseradish peroxidase (HRP) are added forming complexes with the cardiolipin bound antibodies. Following another wash step, the bound enzyme-antibody conjugate is assayed by the addition of tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) as the chromogenic substrate. Color develops in the wells at an intensity proportional to the serum concentration of IgA aCL antibodies. Results are obtained by reading the O.D. of each well with a spectrophotometer. Calibrator sera are provided, with the IgA aCL concentration expressed in APL units. The O.D. values of the controls and patient samples are multiplied by the conversion factor to obtain IgA aCL values, expressed in APL units. Control and patient results are determined from the calibration curve. Refer to Package Insert. FDA UDI

Identifiers

Catalog Number
026-001 FDA UDI
Primary DI / UDI-DI
00855360006052 FDA UDI
FDA Product Code
MID FDA UDI
GMDN Term
Anticardiolipin antibody IVD, kit, enzyme immunoassay (EIA) FDA UDI

Classification

Device Class
Class II FDA UDI
Regulation Number
866.5660 FDA UDI
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

No

FDA UDI

Single Use

Yes

FDA UDI

Implantable

No

FDA UDI

Contains Latex

No

FDA UDI

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

Yes

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

Yes

FDA UDI

Serial Number

No

FDA UDI

Expiration Date

Yes

FDA UDI

Manufacturing Date

No

FDA UDI

Category: Anticardiolipin antibody IVD, kit, enzyme immunoassay (EIA)

REAADS IgA Anti-Cardiolipin Semi-Quantitative Test Kit (96-Well) by Corgenix Medical Corporation — Class II — FDA UDI — listed in FDA GUDID

Similar devices

Also classified as Anticardiolipin antibody IVD, kit, enzyme immunoassay (EIA).

Authorization Coverage (1 country)

Regulatory Authorizations

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Sources (1)

  • FDA UDI d6457755-ee3f-4298-92e9-c210d5eae6c0 36 fields · synced Jun 8, 2026