Skip to content

Reflotron Potassium Test Tabs

by Boehringer Mannheim Corp.

510(k) K904033

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK904033 Date6 Nov 1990ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
CEJ
Device Class
Class II
Regulation
21 CFR Part 862.1600
Advisory Committee
Clinical Chemistry
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Reflotron Potassium Test Tabs are a diagnostic in vitro device used for the quantitative determination of potassium levels in serum or plasma via colorimetric analysis with tetraphenyl borate. This device falls under the classification of Tetraphenyl Borate, Colorimetry, Potassium and is designed for clinical chemistry applications, enabling rapid and accurate measurement of electrolyte levels.

These test tabs are intended for single-use in laboratory settings and require no special sterility beyond standard aseptic handling. Supplied as part of the Reflotron system, they are regulated under FDA 510(k) clearance (K904033) and fall under Class II device classification (Regulation 862.1600). Storage conditions and usage instructions are specified in the accompanying documentation, ensuring proper functionality and compliance with clinical chemistry protocols.

Other devices from Boehringer Mannheim Corp.

See all devices from Boehringer Mannheim Corp. →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical setting or specialty is the Reflotron Potassium Test Tabs designed for use in?

    The Reflotron Potassium Test Tabs are specifically designed for clinical chemistry applications, meaning they are intended for use in laboratory settings where electrolyte levels—particularly potassium—are measured in serum or plasma. This aligns with their classification under the Clinical Chemistry advisory committee and their role in diagnostic testing for electrolyte imbalances.

  • Are the Reflotron Potassium Test Tabs meant for single-use or repeated use, and what does this imply for handling?

    The Reflotron Potassium Test Tabs are intended for single-use only, as explicitly stated in the device description. This means each tab is designed to be used once per test, after which it should be discarded. Single-use ensures accuracy and avoids cross-contamination, requiring proper disposal following standard laboratory protocols for in vitro diagnostic devices.

  • How are these test tabs supplied, and do they require special sterility measures beyond routine lab practices?

    The Reflotron Potassium Test Tabs are supplied as part of the Reflotron system, which is intended for use in laboratory environments. While they do not require special sterility beyond standard aseptic handling (e.g., clean work surfaces, gloves), they must be stored and used according to the accompanying documentation to maintain accuracy and reliability. This aligns with typical practices for in vitro diagnostic devices.

  • What method does the Reflotron Potassium Test Tabs use to measure potassium levels, and how does this differ from traditional lab techniques?

    The Reflotron Potassium Test Tabs use a colorimetric analysis with tetraphenyl borate to quantitatively determine potassium levels in serum or plasma. Unlike traditional lab techniques that may rely on flame photometry or ion-selective electrodes, this method provides a rapid, point-of-care-like result directly from the test tab, making it convenient for clinical chemistry workflows without requiring specialized instrumentation beyond the Reflotron system.

  • What regulatory pathway was followed for the FDA clearance of the Reflotron Potassium Test Tabs, and what does this classification imply for users?

    The Reflotron Potassium Test Tabs were cleared through the FDA 510(k) process under the Traditional pathway, with a decision code of SESE (Substantially Equivalent). This classification places them in FDA Class II, meaning they are subject to general controls and special controls (e.g., performance standards) to ensure safety and effectiveness. Users should confirm compliance with the accompanying documentation and follow clinical chemistry protocols, as the device is regulated under Regulation 862.1600 for tetraphenyl borate-based colorimetric tests.