Skip to content

REGIUS Plate DYEY

by Konica Minolta, Inc.

Ref DYEYModel RP6M110

REGIUS Plate DYEY is a digital imaging storage phosphor screen (EU MDD Class IIa; FDA Class II; FDA product code MQB, Solid State X-Ray Imager (Flat Panel/Digital Imager)) made by Konica Minolta, Inc., registered in EUDAMED on 9 Jul 2026 (Basic UDI-DI B-04560141931091), cleared under FDA 510(k) K092717 on 30 Oct 2009 and listed in FDA GUDID since 19 Sep 2016 (UDI-DI 04560141931091), active as of 25 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 25 Oct 2026

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K092717

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 25 Oct 2026.

Regulatory status

as of registry sync 25 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-04560141931091 Basic UDI-DI 04560141931091UDI-DIDate9 Jul 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number04560141931091 UDI-DI Date19 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Special NumberK092717 Date30 Oct 2009DecidedStatusActive

Official records

From the FDA record

MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 25 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-04560141931091 registered 9 Jul 2026 Active
  • FDA 510(k) K092717 decided 30 Oct 2009 Active
  • FDA GUDID UDI-DI 04560141931091 listed 19 Sep 2016 Listed

Timeline

3 dated events

  1. Cleared FDA 510(k) K092717
  2. Listed FDA GUDID 04560141931091
  3. Registered EUDAMED B-04560141931091

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
REGIUS Plate
Generic name
Digital imaging storage phosphor screen
Device name
Dyey
Model / reference
DYEY, RP6M110
Primary DI / UDI-DI
04560141931091
Basic UDI-DI
B-04560141931091
510(k) Number
FDA product code
MQB
EMDN code
Z11060280 Digital computed radiography (cr) systems - hardware accessories
GMDN term
Digital imaging storage phosphor screen
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.1680
EU registration type
Legacy device (under a directive)
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under DIGITAL COMPUTED RADIOGRAPHY (CR) SYSTEMS - HARDWARE ACCESSORIES.

Other devices from Konica Minolta, Inc.

See all devices from Konica Minolta, Inc. →

Properties

  • Prescription use
  • Serial number
Other properties (21, all answered No)