Active United States

510(k) K210655

Overview

The Reprocessed Eagle Eye Platinum RX Digital IVUS Catheter is an intravascular ultrasound (IVUS) catheter designed for imaging coronary and peripheral vessels. It incorporates a cylindrical ultrasound transducer array that emits acoustic energy to generate real-time cross-sectional images of blood vessels, aiding in the assessment of vessel structure and pathology.

This device is intended for single-use after reprocessing and is classified as a Class II medical device under FDA regulations (870.1200). It features a soft tapered tip, a GlyDx hydrophilic coating for enhanced lubricity, a rapid-exchange lumen for improved pushability, and three radiopaque markers for fluoroscopic visualization. Compatibility with the SyncVision system allows co-registration with angiography, and it is supplied sterile for clinical use.

AI-generated from registry data, 20 Sep 2026.Not verified by deviCERTS or the manufacturer

Regulatory status

as of 27 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK210655 Date25 May 2022ClearedStatusActive

Coverage

1 jurisdiction

United States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not known
  • Not covered

United States — FDA 510(k) Active

Recalls: none on record (FDA, checked 6 Oct 2026)

Specification

510(k)

510(k) Number
FDA Product Code
OWQ
FDA applicant
Innovative Health, LLC
Device Class
Class II
Regulation
21 CFR Part 870.1200
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent