ResponseGrip Interface 2.0

by Nordicneurolab AS

ResponseGrip Interface 2.0, a medical networking interface unit (FDA Class II; FDA product code LNH, System, Nuclear Magnetic Resonance Imaging) made by Nordicneurolab AS, was cleared under FDA 510(k) K092253 on 8 Oct 2009 and listed in FDA GUDID on 22 May 2017 (UDI-DI 07090042054027); the registry lists it as not in commercial distribution (GUDID) as of 12 Nov 2026. FDA recalls on record: 1.

Active United States. Also listed in GUDID (US), not in commercial distribution.

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

1 closed

Documents

510(k) K092253

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 12 Nov 2026.

Regulatory status

as of registry sync 12 Nov 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number07090042054027 UDI-DI Date22 May 2017ListedStatusListed GUDID: not in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK092253 Date8 Oct 2009DecidedStatusActive

Official records

From the FDA record

Device description
ResponseGrip Interface optic-electric interface unit between NordicNeuroLab’s Response Gips and stimulus presentation PC The ResponseGrip consists of two hand-held grips with two buttons each. By pressing the buttons the patient can respond to the presented stimulus. The ResponseGrip is connected to an optical-electrical adapter which converts light to electrical signals. The electrical signal is fed to the Stimulus PC by using standard PC communication interfaces.
MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 12 Nov 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K092253 decided 8 Oct 2009 Active
  • FDA GUDID UDI-DI 07090042054027 listed 22 May 2017 Listed

Recalls

1 recall · FDA

    • Terminated Z-3023-2018 FDA Class II initiated 20 Aug 2018

    Complaints of this version of the power supply unit (LPS) (1.0 and 1.1) being dragged into the magnet bore (MR Scanner).

Timeline

3 dated events

  1. Cleared FDA 510(k) K092253
  2. Listed FDA GUDID 07090042054027
  3. Recall initiated FDA recalls Z-3023-2018

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
ResponseGrip Interface
Generic name
Medical networking interface unit
Model / reference
2.0
Primary DI / UDI-DI
07090042054027
510(k) Number
FDA product code
LNH
GMDN term
Medical networking interface unit
Device class
Class II
Regulation number
892.1000
GUDID distribution status
Not in Commercial Distribution
MRI safety
MR Unsafe

Similar devices

Other devices filed under FDA product code LNH (System, Nuclear Magnetic Resonance Imaging).

Other devices from Nordicneurolab AS

See all devices from Nordicneurolab AS →

Properties

  • Serial number
Other properties (14, all answered No)