Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK772331 Date11 Jan 1978ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DTB
Device Class
Class III
Regulation
21 CFR Part 870.3680
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is a Permanent Pacemaker Electrode, designed for implantation within the cardiovascular system. It facilitates electrical stimulation of the heart to regulate rhythm and support cardiac function in patients requiring pacemaker therapy. The electrode integrates with an adapter to ensure proper connection and functionality within the implanted system.

The resteril process for this implantable electrode and adapter is intended for reuse after sterilization, adhering to strict medical device reprocessing protocols. Supplied as a Class 3 Cardiovascular device under product code DTB, it is cleared for use in regulated clinical settings. Sterilization and handling must comply with FDA guidelines to maintain safety and efficacy, with no explicit MRI safety labeling provided in the data. Authorized under FDA 510(k) clearance K772331, it was originally reviewed in 1978 under the Traditional pathway.

Other devices from Telectronics, Inc.

See all devices from Telectronics, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the resteril process for this implantable electrode and adapter intended to achieve, and how does it differ from a standard single-use device?

    The resteril process for this device is designed to allow reuse of the implantable electrode and adapter after undergoing strict medical device sterilization and reprocessing protocols. Unlike single-use devices, this system is engineered to be cleaned, sterilized, and reimplanted in accordance with FDA guidelines, ensuring safety and efficacy for repeated use in cardiovascular applications. This approach is particularly relevant in clinical settings where resource optimization is important.

  • How is this device classified and what regulatory pathway was used for its FDA clearance?

    This device is classified as a Class 3 Cardiovascular product under FDA product code DTB, indicating it carries higher regulatory scrutiny due to its role in life-sustaining or life-supporting functions. It was cleared via the Traditional 510(k) pathway under FDA clearance K772331, originally reviewed in 1978, with a Substantially Equivalent (SESE) determination by the Cardiovascular (CV) Advisory Committee. This means it was deemed comparable to legally marketed devices of a similar type.

  • Are there any specific storage or handling requirements for this resterilized device to ensure its safety and functionality?

    While the data does not specify exact storage conditions, the resteril process for this device must adhere to FDA reprocessing guidelines to maintain sterility and integrity. Proper handling—including cleaning, sterilization, and storage in a sterile environment—is critical to prevent contamination or degradation before reuse. Clinicians should follow manufacturer-provided instructions for resterilization protocols to ensure compliance with medical device safety standards.

  • What types of patients or clinical scenarios is this device intended for, based on its design and regulatory classification?

    This device is designed for patients requiring permanent pacemaker therapy to regulate heart rhythm and support cardiac function. As a Class 3 Cardiovascular device, it is intended for use in regulated clinical settings where electrical stimulation of the heart is necessary, such as in bradycardia or conduction system disorders. The resteril process allows for reuse in controlled environments where multiple implantations may be required, such as research or specialized cardiac centers.