# Restoris, Rio 206270

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/restoris-rio-206270>
- Manufacturer: [MAKO Surgical Corp.](https://devicerts.com/manufacturers/mako-surgical-corp) (United States)
- Name in the registry: RESTORIS, RIO 206270
- Device class: Class IIa (EU MDR); Class II (US FDA)
- FDA product code: OLO
- EMDN: L091199 ORTHOPAEDIC PROSTHETICS INSTRUMENTS, REUSABLE - OTHER
- GMDN: Orthopaedic implant impactor, reusable (32856)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 08858251002220S2 · UDI-DI 00848486022082 · registered 2026-10-12 · status: Active
- **GUDID** · FDA 510(k) · United States · K170593 · decision 2017-04-18 · decision SESE · status: Active · from GUDID
- **GUDID** · GUDID listing · United States · UDI-DI 00848486022082 · listed 2016-09-24 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K141989 · decision 2014-11-13 · decision SESE · status: Active · from GUDID
- **GUDID** · FDA 510(k) · United States · K121064 · decision 2012-06-06 · decision SESE · status: Active · from GUDID

## Recalls

- Z-1735-2022 · Class II · terminated · initiated 2022-08-08: Certain units have the potential to exhibit infant failures whereby units either arrive non-functional, have the potential to become non-functional, or flash an error light while in use.
- Z-2745-2020 · Class II · terminated · initiated 2020-07-09: Characterization issue associated with the product. This issue may cause a discrepancy during bone preparation in certain Mako Total Hip procedures.
- Z-2925-2018 · Class II · terminated · initiated 2018-07-24: Specific lots of the Vizadisc Knee Procedure Tracking Kit and Vizadisc Hip Procedure Tracking Kit have the potential to be damaged on the Vizadisc reflective material causing an inability to be detected by the camera.
- Z-3182-2018 · Class II · terminated · initiated 2017-12-27: Communication-connection error.
- Z-3131-2017 · Class II · terminated · initiated 2017-08-07: Software discrepancy of not showing all the EE constants, when the screen is filled.
- Z-1411-2017 · Class II · terminated · initiated 2016-12-22: Five (5) AFMEA Risk Control Measures are missing from the MAKO RIO THA Application User Guides
- Z-1193-2017 · Class II · terminated · initiated 2016-09-29: Failure of the Offset Cup Reamer Handle not engaging its mating components.
- Z-1583-2016 · Class II · terminated · initiated 2016-02-23: Potential disassociation of the orientation pin.
- Z-1588-2016 · Class II · terminated · initiated 2015-11-25: Stryker Orthpaedics became aware that there is the potential for the 210540 MAKOplasty Hip Array Kit Laminate 150230 to list two part numbers for the RIO Base Array, which is item #5 on the product table.
- Z-0224-2016 · Class II · terminated · initiated 2015-07-16: The locking pin on the RIO Base Array is damaged during assembly onto the RIO Base Array Connector.
- Z-0829-2015 · Class II · terminated · initiated 2014-10-07: MAKO has identified the potential that the shell impactors may be damaged intraoperatively.
- Z-0830-2015 · Class II · terminated · initiated 2014-10-07: MAKO has identified the potential that the shell impactors may be damaged intraoperatively.
- Z-0828-2015 · Class II · terminated · initiated 2014-10-07: MAKO has identified the potential that the shell impactors may be damaged intraoperatively.
- Z-1508-2016 · Class II · terminated · initiated 2014-04-30: Revision of the field manual

## Identity

- Trade name: Mako [EUDAMED]; RESTORIS, RIO [FDA GUDID (AccessGUDID)]
- Generic name: Orthopaedic implant impactor, reusable [FDA GUDID (AccessGUDID)]
- Device name: TD-01 - MAKO - Class IIa - Shell Impactor [EUDAMED]
- Model / Ref / Catalog: 206270 [EUDAMED, FDA GUDID (AccessGUDID)]; 08858251002220S2 [EUDAMED]

## Identifiers

- Primary DI / UDI-DI: 00848486022082 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 08858251002220S2 [EUDAMED]
- Direct marketing DI: 00848486022082 [EUDAMED]
- FDA product code: OLO [FDA GUDID (AccessGUDID)]
- EMDN code: L091199 [EUDAMED]
- GMDN term: Orthopaedic implant impactor, reusable (32856) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class IIa [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 882.4560 [FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: Netherlands [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Clinical & Handling

- Sterilisation method: Moist Heat or Steam Sterilization [FDA GUDID (AccessGUDID)]

## Properties

- Sterilise before use: Yes [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: Yes [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): Yes [EUDAMED]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Restoris, Rio 206270, MAKO Surgical Corp. deviCERTS medical device catalogue. https://devicerts.com/devices/restoris-rio-206270 (data as of 2026-11-17).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-24
- Statuses computed as of: 2026-11-17
- JSON: <https://devicerts.com/devices/restoris-rio-206270.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/restoris-rio-206270
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.