# Revive Reusable Bladder Support

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/revive-reusable-bladder-support-hhw>
- Manufacturer: [Rinovum Subsidiary 2, LLC](https://devicerts.com/manufacturers/fda-fei-3015417614) (FDA registration: United States)
- Device class: Class II (US FDA)
- FDA product code: HHW

## Overview

*AI-generated summary, 2026-09-19. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The Revive Reusable Bladder Support is a vaginal pessary designed to provide mechanical support for pelvic organs, helping to manage stress urinary incontinence by reducing bladder leakage. Classified as a Class II device, it is intended for internal use in the vaginal canal to offer sustained pressure and alignment to the pelvic floor.

This reusable device is supplied sterile upon first use and intended for repeated use with proper cleaning and maintenance. It is not MRI-safe and comes in a single size, requiring no additional accessories. The device holds an FDA 510(k) clearance under the Obstetrics/Gynecology advisory committee and is regulated under the classification code HHW, with registration numbers listed in the FDA database.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K183468 · decision 2019-01-25 · decision SESE · status: Active

## Recalls

- Z-1952-2019 · Class II · terminated · initiated 2019-05-02: The product is unable to meet the use life of 31 cycles and may split or crack at the base of the "petals" after repeated use but within the use life of the product (31 uses).

## Identifiers

- 510(k) Number: K183468 [FDA 510(k)]
- FDA product code: HHW [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 884.3575 [FDA 510(k)]
- Advisory committee: Obstetrics/Gynecology [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: Revive Reusable Bladder Support, Rinovum Subsidiary 2, LLC. deviCERTS medical device catalogue. https://devicerts.com/devices/revive-reusable-bladder-support-hhw (data as of 2026-11-23).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-06
- Statuses computed as of: 2026-11-23
- JSON: <https://devicerts.com/devices/revive-reusable-bladder-support-hhw.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/revive-reusable-bladder-support-hhw
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.