Revolution Ascend
by GE Healthcare Japan Corporation
Ref Revolution AscendModel Revolution Ascend, Revolution Ascend Elite, Revolution Ascend Plus, Revolution Ascend Select
Revolution Ascend is a full-body CT system (EU MDR Class IIb; FDA Class II; FDA product code JAK, System, x-ray, tomography, computed) made by GE Healthcare Japan Corporation, registered in EUDAMED on 17 May 2022 (Basic UDI-DI 8406821BUG00117H2), cleared under FDA 510(k) K213938 on 4 Feb 2022 (1 earlier submission) and listed in FDA GUDID since 26 Nov 2020 (UDI-DI 00840682146173), active as of 24 Oct 2026. 4 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
4 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number8406821BUG00117H2 00840682146173 | Date17 May 2022 | StatusActive |
| United States | FDA 510(k) GUDID | NumberK213938 | Date4 Feb 2022 | StatusActive |
| United States | GUDID listing GUDID | Number00840682146173 | Date26 Nov 2020 | StatusListed |
Official records
- EUDAMED public site 8406821BUG00117H2
- AccessGUDID record 00840682146173
- FDA 510(k) database K213938
- FDA 510(k) database K203169
From the FDA record
- Device description
- NGX Gantry common top asm with UDI
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 8406821BUG00117H2 registered 17 May 2022 Active
- FDA 510(k) K213938 decided 4 Feb 2022 Active
- FDA GUDID UDI-DI 00840682146173 listed 26 Nov 2020 Listed
Recalls
-
- Ongoing Z-2149-2026
GE HealthCare has become aware of a potential security vulnerability impacting AW Server deployed via Edison Health Link (EHL) based CT Smart Subscription used in conjunction with certain Revolution Apex, Revolution Ascend, and Revolution CT systems.
-
- Ongoing Z-0605-2025
GE HealthCare has become aware of a potential issue on certain Discovery, Optima, Revolution series CT systems, and certain operator console upgrades that can result in rotated CT images. Particularly with helical, cine, and cardiac (if applicable) scan modes, after the first image of an exam, each subsequent image can be rotated by an increasing amount. The amount of progressive image rotation is dependent on the gantry speed and the duration of the scan. The final image in the exam can be rotated up to a maximum of ~56 degrees. The entire anatomy rotates as a whole by equal degrees, without distortion, and the anatomical positioning and z-axis of the images remains correct. Small degrees of image rotation might not be noticed. If image rotation is noticed and necessitates a rescan of the patient, the same image rotation will reoccur.
-
- Ongoing Z-1511-2022
As a result of unclear guidance in the service manual, the table can drop during a specific service activity if the wrong screws are removed by the service personnel without the appropriate table supports in place resulting in injury to service personnel.
-
- Ongoing Z-2023-2021
When adding one or more intended scan groups names must contain only letters, numbers (0-9), or a space or the user interface will not update to confirm the intended group(s) has been added to the acquisition.
Timeline
- Cleared FDA 510(k) K203169
- Listed FDA GUDID 00840682146173
- Recall initiated FDA recalls Z-2023-2021
- Cleared FDA 510(k) K213938
- Registered EUDAMED 8406821BUG00117H2
- Recall initiated FDA recalls Z-1511-2022
- Recall initiated FDA recalls Z-0605-2025
- Recall initiated FDA recalls Z-2149-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Revolution Ascend EUDAMEDRevolution GUDID
- Generic name
- Full-body CT system
- Model / Ref / Catalog
- Revolution Ascend EUDAMEDRevolution Ascend Elite EUDAMEDRevolution Ascend Plus EUDAMEDRevolution Ascend Select EUDAMEDAscend GUDIDRevolutionAscend GUDID
- Primary DI / UDI-DI
- 00840682146173
- Basic UDI-DI
- 8406821BUG00117H2
- FDA product code
- JAK
- EMDN code
- Z11030606 Computed tomographs - 128 layers or more but less than 256 layers
- GMDN term
- Full-body CT system
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 892.1750
- EU registration type
- Standard device
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Manufacturer details
- EUDAMED SRN
- JP-MF-000009291
- Authorised representative
- GE Medical Systems SCS FR-AR-000000344
Similar devices in this category
Other devices filed under COMPUTED TOMOGRAPHS - 128 LAYERS OR MORE BUT LESS THAN 256 LAYERS.
- CT 5300 728285 by Philips Healthcare (Suzhou) Co., Ltd.
- System SOMATOM X.ceed 11330002 by Siemens Healthineers AG
- Supria by FUJIFILM CORPORATION
- FCT iStream by FUJIFILM CORPORATION
- Photonova Spectra 5590000-50 by GE Medical Systems, L.L.C.
- CT Areta RT/Rembra RT Upgrades 728385 by Philips Healthcare (Suzhou) Co., Ltd.
- NeuViz Prime none by Neusoft Medical Systems Co., Ltd.
- Revolution Altitude Plus by GE HANGWEI MEDICAL SYSTEMS CO., LTD.
- Console Generation Upgrade by GE HANGWEI MEDICAL SYSTEMS CO., LTD.
- Revolution by GE HEALTHCARE JAPAN CORPORATION