Skip to content

Revolution Ascend

by GE Healthcare Japan Corporation

Ref Revolution AscendModel Revolution Ascend, Revolution Ascend Elite, Revolution Ascend Plus, Revolution Ascend Select

Revolution Ascend is a full-body CT system (EU MDR Class IIb; FDA Class II; FDA product code JAK, System, x-ray, tomography, computed) made by GE Healthcare Japan Corporation, registered in EUDAMED on 17 May 2022 (Basic UDI-DI 8406821BUG00117H2), cleared under FDA 510(k) K213938 on 4 Feb 2022 (1 earlier submission) and listed in FDA GUDID since 26 Nov 2020 (UDI-DI 00840682146173), active as of 24 Oct 2026. 4 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

4 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number8406821BUG00117H2 Basic UDI-DI 00840682146173UDI-DIDate17 May 2022RegisteredStatusActive
United StatesFDA 510(k) GUDID from GUDID NumberK213938 Date4 Feb 2022IssuedStatusActive
United StatesGUDID listing GUDID Number00840682146173 UDI-DI Date26 Nov 2020ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
NGX Gantry common top asm with UDI
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 8406821BUG00117H2 registered 17 May 2022 Active
  • FDA 510(k) K213938 decided 4 Feb 2022 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00840682146173 listed 26 Nov 2020 Listed

Recalls

4 recalls · 4 ongoing · FDA

    • Ongoing Z-2149-2026 FDA Class II initiated 26 Mar 2026 UDI-DI 00840682146173 listed

    GE HealthCare has become aware of a potential security vulnerability impacting AW Server deployed via Edison Health Link (EHL) based CT Smart Subscription used in conjunction with certain Revolution Apex, Revolution Ascend, and Revolution CT systems.

    • Ongoing Z-0605-2025 FDA Class II initiated 5 Nov 2024 UDI-DI 00840682146173 listed

    GE HealthCare has become aware of a potential issue on certain Discovery, Optima, Revolution series CT systems, and certain operator console upgrades that can result in rotated CT images. Particularly with helical, cine, and cardiac (if applicable) scan modes, after the first image of an exam, each subsequent image can be rotated by an increasing amount. The amount of progressive image rotation is dependent on the gantry speed and the duration of the scan. The final image in the exam can be rotated up to a maximum of ~56 degrees. The entire anatomy rotates as a whole by equal degrees, without distortion, and the anatomical positioning and z-axis of the images remains correct. Small degrees of image rotation might not be noticed. If image rotation is noticed and necessitates a rescan of the patient, the same image rotation will reoccur.

    • Ongoing Z-1511-2022 FDA Class II initiated 2 Jun 2022 UDI-DI 00840682146173 listed

    As a result of unclear guidance in the service manual, the table can drop during a specific service activity if the wrong screws are removed by the service personnel without the appropriate table supports in place resulting in injury to service personnel.

    • Ongoing Z-2023-2021 FDA Class II initiated 30 Jun 2021

    When adding one or more intended scan groups names must contain only letters, numbers (0-9), or a space or the user interface will not update to confirm the intended group(s) has been added to the acquisition.

Timeline

8 dated events

  1. Cleared FDA 510(k) K203169
  2. Listed FDA GUDID 00840682146173
  3. Recall initiated FDA recalls Z-2023-2021
  4. Cleared FDA 510(k) K213938
  5. Registered EUDAMED 8406821BUG00117H2
  6. Recall initiated FDA recalls Z-1511-2022
  7. Recall initiated FDA recalls Z-0605-2025
  8. Recall initiated FDA recalls Z-2149-2026

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Revolution Ascend EUDAMED
Revolution GUDID
Generic name
Full-body CT system
Model / Ref / Catalog
Revolution Ascend EUDAMED
Revolution Ascend Elite EUDAMED
Revolution Ascend Plus EUDAMED
Revolution Ascend Select EUDAMED
Ascend GUDID
RevolutionAscend GUDID
Primary DI / UDI-DI
00840682146173
Basic UDI-DI
8406821BUG00117H2
510(k) Number
FDA product code
JAK
EMDN code
Z11030606 Computed tomographs - 128 layers or more but less than 256 layers
GMDN term
Full-body CT system
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
892.1750
EU registration type
Standard device
EU market of registration
France
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
JP-MF-000009291
Authorised representative
GE Medical Systems SCS FR-AR-000000344

Similar devices in this category

Other devices filed under COMPUTED TOMOGRAPHS - 128 LAYERS OR MORE BUT LESS THAN 256 LAYERS.

Other devices from GE Healthcare Japan Corporation

See all devices from GE Healthcare Japan Corporation →

Properties

  • Measuring function
  • Prescription use
  • Serial number
Other properties (22, all answered No)