Skip to content

Revolution PC

by Sorin Group Italia SRL

Ref 050300000

Revolution PC (050300700) is a cardiopulmonary bypass system centrifugal pump (EU MDR Class IIa; FDA Class II; FDA product code KFM, Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type) made by Sorin Group Italia SRL, registered in EUDAMED on 4 Sep 2026 (Basic UDI-DI 8033178PUMPREVCPBQ9), cleared under FDA 510(k) K190650 on 7 Aug 2019 (1 earlier submission) and listed in FDA GUDID since 23 Jul 2014 (UDI-DI 08033178104777), active as of 23 Oct 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

2 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number8033178PUMPREVCPBQ9 Basic UDI-DI 08033178104777UDI-DIDate4 Sep 2026RegisteredStatusActive
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK190650 Date7 Aug 2019DecidedStatusActive
United StatesGUDID listing GUDID Number08033178104777 UDI-DI Date23 Jul 2014ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 8033178PUMPREVCPBQ9 registered 4 Sep 2026 Active
  • FDA 510(k) K190650 decided 7 Aug 2019 Active· +1 more in the status table
  • FDA GUDID UDI-DI 08033178104777 listed 23 Jul 2014 Listed

Recalls

2 recalls · FDA

  • 2 recalls, same reason

    • Terminated Z-0193-2010 FDA Unclassified (pre-2012) initiated 25 Sep 2009
    • Terminated Z-0192-2010 FDA Unclassified (pre-2012) initiated 25 Sep 2009

    A weakness in the plastic packaging tray could cause the tray to crack; compromising product sterility.

Timeline

6 dated events

  1. Cleared FDA 510(k) K030462
  2. Recall initiated FDA recalls Z-0193-2010
  3. Recall initiated FDA recalls Z-0192-2010
  4. Listed FDA GUDID 08033178104777
  5. Cleared FDA 510(k) K190650
  6. Registered EUDAMED 8033178PUMPREVCPBQ9

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Revolution
Generic name
Cardiopulmonary bypass system centrifugal pump
Device name
Centrifugal Pumps
Model / Ref / Catalog
050300000 EUDAMED
REVOLUTION PC GUDID
050300700 GUDID
Primary DI / UDI-DI
08033178104777
Basic UDI-DI
8033178PUMPREVCPBQ9
510(k) Number
FDA product code
KFM
EMDN code
C03010199 Extracorporeal circulation kits - other
GMDN term
Cardiopulmonary bypass system centrifugal pump
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
870.4360
EU registration type
Standard device
EU market of registration
Italy
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
050300000
GUDID
REVOLUTION PC
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under EXTRACORPOREAL CIRCULATION KITS.

Other devices from Sorin Group Italia SRL

See all devices from Sorin Group Italia SRL →

Properties

  • Supplied sterile
  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (20, all answered No)