Skip to content

RIACOAT T-4

by Immuno Assay Corp.

510(k) K833745

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 5 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 5 Oct 2026. What this means

Regulatory status

as of registry sync 5 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK833745 Date4 Jan 1984ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 5 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
CDX
Device Class
Class II
Regulation
21 CFR Part 862.1700
Advisory Committee
Clinical Chemistry
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The RIACOAT T-4 is a Radioimmunoassay Kit for Total Thyroxine (T4), classified under Clinical Chemistry. It is designed to measure total thyroxine levels in plasma or serum samples using a coated-tube radioimmunoassay method. The assay relies on competitive binding between labeled and unlabeled thyroxine in the sample, enabling quantitative determination of T4 concentrations.

This device is supplied as a single-use diagnostic kit and requires incubation of undiluted samples, standards, and controls with tracer for 2 hours in thyroxine antibody-coated tubes. It is intended for in vitro diagnostic use in clinical chemistry laboratories, adhering to FDA clearance under 510(k) K833745 with a product code of CDX. No MRI safety or sterility specifications are noted in the available data.

Other devices from Immuno Assay Corp.

See all devices from Immuno Assay Corp. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the RIACOAT T-4 used for?

    The RIACOAT T-4 is a radioimmunoassay kit designed specifically for measuring total thyroxine (T4) levels in plasma or serum samples. It employs a coated-tube method where labeled and unlabeled thyroxine compete for binding sites on thyroxine antibody-coated tubes. This competitive binding allows for precise quantitative measurement of T4 concentrations, which is critical for diagnosing and monitoring thyroid-related conditions.

  • How is the RIACOAT T-4 kit supplied and used?

    The RIACOAT T-4 is supplied as a single-use diagnostic kit. To perform the assay, undiluted samples, standards, and controls are incubated with tracer in the thyroxine antibody-coated tubes for 2 hours. This incubation period enables the competitive binding reaction to occur, allowing for the determination of T4 levels. The kit is intended exclusively for in vitro diagnostic use in clinical chemistry laboratories.

  • Is the RIACOAT T-4 kit sterile?

    The provided data does not specify any sterility requirements or claims for the RIACOAT T-4 kit. Users should follow standard laboratory protocols for handling and preparing samples to ensure safety and accuracy, particularly since it is intended for in vitro diagnostic use.

  • Can the RIACOAT T-4 kit be reused?

    The RIACOAT T-4 is explicitly designed as a single-use diagnostic kit. Reusing components could compromise the accuracy of results and potentially introduce contamination or cross-reactivity, which is why it is not recommended. Each kit is intended for one assay cycle only.

  • What regulatory pathway does the RIACOAT T-4 follow?

    The RIACOAT T-4 received FDA clearance under the 510(k) pathway, specifically with clearance number K833745. It is classified under Clinical Chemistry and is substantially equivalent to a predicate device, as determined by the FDA. The product code assigned is CDX, indicating its classification in diagnostic clinical chemistry.