Richards Torp Replacement Ossicular Prosthesis, Total

by Smith & Nephew Richards, Inc.

510(k) K952549

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK952549 Date3 Jul 1995ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 6 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
Richards Torp
510(k) Number
FDA Product Code
ETA
Device Class
Class II
Regulation
21 CFR Part 874.3495
Advisory Committee
Ear, Nose, Throat
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Richards Torp is a Replacement, Ossicular Prosthesis, Total, classified under FDA product code ETA. This device is designed to restore conductive hearing by replacing damaged ossicles in the middle ear, particularly in cases of otosclerosis or other conditions causing ossicular chain disruption. Constructed to mimic the natural function of the ossicular chain, it facilitates sound transmission from the tympanic membrane to the inner ear, improving auditory performance in patients with conductive hearing loss.

Intended for surgical use in otolaryngology settings, the Richards Torp is supplied sterile and intended for single-use. It is classified as a Class II medical device under FDA regulations (874.3495) and holds a FDA 510(k) clearance (K952549) with a Substantially Equivalent determination. The device is manufactured by Smith & Nephew Richards, Inc., and its specifications align with Ear, Nose, and Throat (ENT) surgical applications. No MRI safety information is provided, and storage conditions are not detailed in the available data.

Other devices from Smith & Nephew Richards, Inc.

See all devices from Smith & Nephew Richards, Inc. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Richards Torp used for?

    The Richards Torp is an ossicular prosthesis intended to replace damaged ossicles in the middle ear, restoring conductive hearing in patients with conditions like otosclerosis or ossicular chain disruption. By mimicking the natural function of the ossicular chain, it facilitates sound transmission from the tympanic membrane to the inner ear, improving auditory performance in individuals with conductive hearing loss.

  • Is the Richards Torp sterile and single-use?

    Yes, the Richards Torp is supplied sterile and is intended for single-use only. This ensures patient safety by preventing cross-contamination and maintains the device’s integrity for optimal performance during surgery.

  • What are the key specifications of the Richards Torp?

    The Richards Torp is classified as a Class II medical device under FDA regulations (874.3495) and holds an FDA 510(k) clearance (K952549) with a Substantially Equivalent determination. It is designed specifically for otolaryngology procedures, particularly in Ear, Nose, and Throat (ENT) surgeries, and is manufactured by Smith & Nephew Richards, Inc.

  • Are there any special storage instructions for the Richards Torp?

    The provided data does not specify storage conditions for the Richards Torp. Clinicians should follow standard sterile medical device storage guidelines until further information is available.

  • Can the Richards Torp be used in MRI procedures?

    No MRI safety information is provided for the Richards Torp. Clinicians should avoid using it in MRI environments unless explicit safety data confirms compatibility, as the device’s material properties or components may not be MRI-safe.