RingLoc Hip System XL-155232 is a non-constrained polyethylene acetabular liner (FDA Class II) made by Biomet Orthopedics, Inc., cleared under FDA 510(k) K062997 on 8 Dec 2006 (1 earlier submission) and listed in FDA GUDID since 24 Oct 2015 (UDI-DI 00880304437562), active as of 23 Oct 2026. 3 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

3 closed

Documents

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00880304437562 UDI-DI Date24 Oct 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK062997 Date8 Dec 2006DecidedStatusActive

Official records

From the FDA record

MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K062997 decided 8 Dec 2006 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00880304437562 listed 24 Oct 2015 Listed

Recalls

3 recalls · FDA

    • Terminated Z-1860-2017 FDA Class II initiated 17 Feb 2017

    Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components.

    • Terminated Z-1143-2012 FDA Not yet classified initiated 7 Feb 2012

    Biomet initiated this action after complaints were received where OOS AVL Bushing Sets were opened during OSS knee replacement procedures, and were found to contain two tabbed bushings.

    • Terminated Z-1449-2012 FDA Unclassified (pre-2012) initiated 13 Sep 2011

    Devices with a specification for a +6mm neck length were incorrectly labeled for a +3mm neck length specification.

Timeline

6 dated events

  1. Cleared FDA 510(k) K042051
  2. Cleared FDA 510(k) K062997
  3. Recall initiated FDA recalls Z-1449-2012
  4. Recall initiated FDA recalls Z-1143-2012
  5. Listed FDA GUDID 00880304437562
  6. Recall initiated FDA recalls Z-1860-2017

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
RingLoc Hip System
Generic name
Non-constrained polyethylene acetabular liner
Model / Ref / Catalog
XL-155232
Primary DI / UDI-DI
00880304437562
510(k) Number
FDA product code
JDI, LPH, LZO
GMDN term
Non-constrained polyethylene acetabular liner
Device class
Class II
Regulation number
888.3350, 888.3358, 888.3353
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe

Similar devices in this category

Other devices filed under Non-constrained polyethylene acetabular liner.

Other devices from Biomet Orthopedics, Inc.

See all devices from Biomet Orthopedics, Inc. →

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (9, all answered No)