Rio 160230
Part of a family of 6 devices: see the family page
Ref 160230Model 08858251002247SN
Rio 160230 is a patient positioning sensor (EU MDR Class I; FDA Class II; FDA product code OLO, Orthopedic stereotaxic instrument) made by MAKO Surgical Corp., registered in EUDAMED on 12 Oct 2026 (Basic UDI-DI 08858251002247SN), cleared under FDA 510(k) K170593 on 18 Apr 2017 (2 earlier submissions) and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 00848486020385), active as of 24 Oct 2026. 14 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number08858251002247SN 00848486020385 | Date12 Oct 2026 | StatusActive |
| United States | FDA 510(k)SESE GUDID | NumberK170593 | Date18 Apr 2017 | StatusActive |
| United States | GUDID listing GUDID | Number00848486020385 | Date24 Sep 2016 | StatusListed |
Official records
- EUDAMED public site 08858251002247SN
- AccessGUDID record 00848486020385
- FDA 510(k) database K170593
- FDA 510(k) database K141989
- FDA 510(k) database K121064
From the FDA record
- Device description
- REGISTRATION ARRAY
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI 08858251002247SN registered 12 Oct 2026 Active
- FDA 510(k) K170593 decided 18 Apr 2017 Active
- FDA GUDID UDI-DI 00848486020385 listed 24 Sep 2016 Listed
Recalls
-
- Terminated Z-1735-2022
Certain units have the potential to exhibit infant failures whereby units either arrive non-functional, have the potential to become non-functional, or flash an error light while in use.
-
- Terminated Z-2745-2020
Characterization issue associated with the product. This issue may cause a discrepancy during bone preparation in certain Mako Total Hip procedures.
-
- Terminated Z-2925-2018
Specific lots of the Vizadisc Knee Procedure Tracking Kit and Vizadisc Hip Procedure Tracking Kit have the potential to be damaged on the Vizadisc reflective material causing an inability to be detected by the camera.
-
- Terminated Z-3182-2018
Communication-connection error.
-
- Terminated Z-3131-2017
Software discrepancy of not showing all the EE constants, when the screen is filled.
-
- Terminated Z-1411-2017
Five (5) AFMEA Risk Control Measures are missing from the MAKO RIO THA Application User Guides
-
- Terminated Z-1193-2017
Failure of the Offset Cup Reamer Handle not engaging its mating components.
-
- Terminated Z-1583-2016
Potential disassociation of the orientation pin.
-
- Terminated Z-1588-2016
Stryker Orthpaedics became aware that there is the potential for the 210540 MAKOplasty Hip Array Kit Laminate 150230 to list two part numbers for the RIO Base Array, which is item #5 on the product table.
-
- Terminated Z-0224-2016
The locking pin on the RIO Base Array is damaged during assembly onto the RIO Base Array Connector.
-
- Terminated Z-0829-2015
- Terminated Z-0830-2015
- Terminated Z-0828-2015
MAKO has identified the potential that the shell impactors may be damaged intraoperatively.
-
- Terminated Z-1508-2016
Revision of the field manual
Timeline
- Listed FDA GUDID 00848486020385
- Recall initiated FDA recalls Z-1193-2017
- Recall initiated FDA recalls Z-1411-2017
- Cleared FDA 510(k) K170593
- Recall initiated FDA recalls Z-3131-2017
- Recall initiated FDA recalls Z-3182-2018
- Recall initiated FDA recalls Z-2925-2018
- Recall initiated FDA recalls Z-2745-2020
- Recall initiated FDA recalls Z-1735-2022
- Registered EUDAMED 08858251002247SN
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Mako EUDAMEDRio GUDID
- Generic name
- Patient positioning sensor
- Device name
- TD-01 - MAKO - Class I - Stereotactic Orthopedic Surgery Instruments - Metal
- Model / Ref / Catalog
- 160230, 08858251002247SN
- Primary DI / UDI-DI
- 00848486020385
- Basic UDI-DI
- 08858251002247SN
- Direct marketing DI
- 00848486020385
- FDA product code
- OLO
- EMDN code
- Z12130480 Stereotactic orthopaedic surgery instruments - hardware accessories
- GMDN term
- Patient positioning sensor
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 882.4560
- EU registration type
- Standard device
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class I | Class II |
Similar devices in this category
Other devices filed under STEREOTACTIC ORTHOPAEDIC SURGERY INSTRUMENTS - HARDWARE ACCESSORIES.
- ROSA PPK MED CUT GUIDE A-L 20-8020-030-00 by Zimmer CAS
- Pin Ø3.2 L=47 mm HA3.5 Meche Head Triangle 04.01.10.1152 by Medacta International SA
- Universal Navigation Adaptor Set 302011012 by MEDOS INTERNATIONAL SARL
- NextAR TKA Platform 02.23.10.0013 by Medacta International SA
- SPINE REFERENCING KIT SS 9736696 by Medtronic Navigation Inc.
- 286755005N by MEDOS INTERNATIONAL SARL
- OMNIBotics NV-CRD06 by OMNIlife science, Inc.
- OMNIBotics NV-LPT05 by OMNIlife science, Inc.
- STEALTH EM SPINE RETRACTORS KIT AL 9736694 by Medtronic Navigation Inc.
- VELYS Connectors 4515-70-105 by DePuy Ireland UC