Roche Cobas Integra Analyzer, Reagent Cassettes

by Roche Diagnostic Systems, Inc. 510(k)

Active United States

510(k) K951595

Regulatory status

as of 28 Oct 2026

Recall ongoing on a related submission. 1 ongoing FDA recall. See recalls

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK951595 Date8 Sep 1995ClearedStatusActive

Coverage

1 jurisdiction

United States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not known
  • Not covered

United States — FDA 510(k) Active

Recalls

7 recalls · 1 ongoing · FDA

    • Ongoing Z-1675-2021 FDA Class II initiated 26 Apr 2021 via K951595, on the same 510(k)

    Roche received several complaints regarding increased control recovery and discrepant elevated results for the Iron Gen.2 (IRON2) assay on the cobas c311, 501, and 502 analyzers and on the COBAS Integra 400 plus analyzer.

    • Terminated Z-0100-2017 FDA Class II initiated 15 Jul 2016 via K951595, on the same 510(k)

    Roche has received four reports of injury caused by the sharp edge of the center guide rail of an analyzers sample rack tray. The cleaning procedure for the sample rack tray has been revised to clarify the cleaning process.

    • Terminated Z-0168-2014 FDA Class II initiated 16 Sep 2013 via K951595, on the same 510(k)

    Roche COBAS INTEGRA 800 system, Software Version 9864.C2 does not perform necessary ISE Service Actions. Whenever the ISE rack is removed, the ISE counters in the software are reset to zero and the corresponding Service Actions are not conducted automatically by the system. Additionally, certain maintenance activities that have to be performed manually by the operator are not requested on the sof

    • Terminated Z-0696-2013 FDA Class III initiated 19 Nov 2012 via K951595, on the same 510(k)

    A software security issue with Oracles TNS-Listener component has been identified. TNS-Listener is supplied with the Roche COBAS INTEGRA 400/400 plus Analyzers. The Oracle TNS-Listener can be considered as an authentication and redirection component between the client and the database inside the Roche product. This means an attacker could register their own non-Roche database via remote access

  • 2 recalls, same reason

    • Terminated Z-0007-2009 FDA Unclassified (pre-2012) initiated 11 Jun 2008 via K951595, on the same 510(k)
    • Terminated Z-0012-2009 FDA Unclassified (pre-2012) initiated 11 Jun 2008

    Some of the labels are glossy, resulting in the bar code being difficult to read by the bar code reader.

    • Terminated Z-0667-03 FDA Unclassified (pre-2012) initiated 13 Feb 2003 via K951595, on the same 510(k)

    After a cassette change, patient results and controls may be up to 40% too low or too high due to calibration factor variation.

Recalls marked "via" name another device cleared under the same FDA submission as this one.

Specification

510(k)

510(k) Number
FDA Product Code
CGX
Device Class
Class II
Regulation
21 CFR Part 862.1225
Advisory Committee
Clinical Chemistry
FDA Decision
SESE Substantially Equivalent

Other devices from Roche Diagnostic Systems, Inc.

See all devices from Roche Diagnostic Systems, Inc. →