Roche Diagnostics Omni S Analyzer
510(k) K032311
Roche Diagnostics Omni S Analyzer is a medical device (FDA Class II; FDA product code CEM, Electrode, Ion Specific, Potassium) made by Roche Diagnostics Corp., cleared under FDA 510(k) K032311 on 17 Oct 2003, active as of 22 Oct 2026. 4 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK032311 | Date17 Oct 2003 | StatusActive |
Official records
- FDA 510(k) database K032311
From the FDA record
- Received by the FDA
- 28 Jul 2003
- FDA decision
- 17 Oct 2003 (Substantially Equivalent)
- FDA review time
- 81 days from receipt to decision
- Public document
- 510(k) summary on file with the FDA
Recalls
-
- Terminated Z-1610-2018
- Terminated Z-1611-2018
- Terminated Z-1612-2018
- Terminated Z-1613-2018
The software responsible for starting scheduled AutoQC measurements (scheduler) will not activate.
-
- Terminated Z-0673-2017
Incorrect Urea results may be generated sporadically on cobas b 221<6>Roche OMNI S6 system and cannot be detected by QC. QC measurement results can be affected as well. This issue is only detectable if comparison result of a second measurement is available. The cause for this issue is an error in the software measurement procedure. In children, decreased urea results can point at inborn disorders or urea cycle. Therefore, false normal urea values could lead to delayed/incorrect diagnosis of such a disorder. Besides the patients most at risk, the risk for the overall patient population with falsely low or high values is considered remote. No severe adverse health effects are expected; but, unnecessary diagnostic measures may be initiated. Falsely normal results may result in further necessary examination not being carried out, with the possibility of a delay in the diagnosis and treatment. A medical risk cannot entirely be excluded.
-
- Terminated Z-2330-2015
The affected S2 fluid packs may generate a transponder error when the fluid pack is loaded on to the cobas b 221 system. The error prevents the fluid from being recognized by the system and the instrument cannot start measurements until the affected S2 Fluid Pack is replaced.
-
- Terminated Z-1041-2015
Chemical component of the F3 Fluid pack and environmental bacterial contamination causes a positive bias up to 39% at 4.1 mmol/l for the glucose measurement and 30% at 4.12 mmol/l for lactate. Urea readings are unaffected.
-
- Terminated Z-0064-2015
The default references for normal values are inconsistent between cobas b 221 and other blood gas instruments. In addition, the reference ranges are different when comparing with corresponding ranges listed in the Instructions for Use for the analyzer and the reference literature source.
-
- Terminated Z-1315-2014
Reference electrode used beyond the guaranteed in-use 52 week lifetime,may leak and potentially cause erroneous pH and/or sodium results. Other Ion parameters are not affected.
Timeline
- Cleared FDA 510(k) K032311
- Recall initiated FDA recalls Z-1315-2014
- Recall initiated FDA recalls Z-0064-2015
- Recall initiated FDA recalls Z-1041-2015
- Recall initiated FDA recalls Z-2330-2015
- Recall initiated FDA recalls Z-0673-2017
- Recall initiated FDA recalls Z-1610-2018
- Recall initiated FDA recalls Z-1611-2018
- Recall initiated FDA recalls Z-1612-2018
- Recall initiated FDA recalls Z-1613-2018
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA product code
- CEM
- Device class
- Class II
- Regulation
- 21 CFR Part 862.1600
- Advisory committee
- Clinical Chemistry
- FDA decision
- SESE Substantially Equivalent
Similar devices
Other devices filed under FDA product code CEM (Electrode, Ion Specific, Potassium).
- DYNA-LYTE 2000 by Abbott Diagnostics
- SODIUM/POTASSIUM REAGENT KITS by Chem-Elec, Inc.
- POLY-CHEM 90 ISE MODULE by POLYMEDCO, INC.
- LYTENING 2Z LYTENING SYSTEM 31 by Baxter Healthcare Corp
- MODIFIED APSARA CLINICAL DIAGNOSTIC ANALYZER by Datachem, Inc.
- ABL90 FLEX PLUS System by Radiometer Medical ApS
- Clot catcher 906-020 by Radiometer Medical ApS
- SmartLyte® Plus Electrolyte Analyzer Na+/K+/Cl-/Ca++/Li+ by DIAMOND DIAGNOSTICS Inc
- DIMENSION CLINICAL CHEMISTRY SYSTEM, MODEL XPAND by Dade Behring, Inc.
- CHEM PRO 1000 CHEMISTRY ANALYSIS by Sen Tech Medical Corp.