← Back to catalogue

ROTEM® sigma

EUDAMEDFDA UDI

Class A (EU MDR)

Ref 211000

by Tem Innovations GmbH

Identity

Trade Name
ROTEM® sigma EUDAMED
ROTEM® FDA UDI
Generic Name
Coagulation analyser IVD, laboratory FDA UDI
Device Name
ROTEM® sigma EUDAMED
The ROTEM sigma is an in vitro diagnostic (IVD) whole blood hemostasis system intended for use in the evaluation of coagulopathies in Point of Care (POC) or laboratory settings. It uses rotational thromboelastometry to provide semiquantitative information about the coagulation state of a blood sample. The ROTEM sigma system records the kinetic changes in a sample of 3.2% citrated whole blood during clot formation, as well as when the sample clot retracts and/or lyses. Several parameters are measured and reported for this purpose. The graphical presentation reflects the various physiological results, which describe the interaction between coagulation factors and inhibitors, fibrinogen, platelets, and the fibrinolysis system. Additionally, the effect of certain drugs influencing hemostasis, in particular some anticoagulants (e.g. heparin), can be detected. FDA UDI
Model / Reference
211000 EUDAMED
sigma FDA UDI
Description
The ROTEM sigma is an in vitro diagnostic (IVD) whole blood hemostasis system intended for use in the evaluation of coagulopathies in Point of Care (POC) or laboratory settings. It uses rotational thromboelastometry to provide semiquantitative information about the coagulation state of a blood sample. The ROTEM sigma system records the kinetic changes in a sample of 3.2% citrated whole blood during clot formation, as well as when the sample clot retracts and/or lyses. Several parameters are measured and reported for this purpose. The graphical presentation reflects the various physiological results, which describe the interaction between coagulation factors and inhibitors, fibrinogen, platelets, and the fibrinolysis system. Additionally, the effect of certain drugs influencing hemostasis, in particular some anticoagulants (e.g. heparin), can be detected. FDA UDI

Identifiers

Catalog Number
211000 FDA UDI
Primary DI / UDI-DI
04260160470372 EUDAMEDFDA UDI
Basic UDI-DI
4260160470372RT EUDAMED
510(k) Number
K201440 FDA UDI
FDA Product Code
JPA FDA UDI
EMDN Code
W0202029001 THROMBELASTOGRAPHS EUDAMED
GMDN Term
Coagulation analyser IVD, laboratory FDA UDI

Classification

Device Class
Class A EUDAMED
Class II FDA UDI
Regulation Number
864.5425 FDA UDI
Market of Registration
Germany EUDAMED
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

No

EUDAMEDFDA UDI

Single Use

No

FDA UDI

Implantable

No

FDA UDI

Contains Latex

No

FDA UDI

Human Tissues

No

EUDAMED

Animal Tissues

No

EUDAMED

Microbial Substances

No

EUDAMED

Reagent

No

EUDAMED

Self Testing

No

EUDAMED

Near-Patient Testing

Yes

EUDAMED

Professional Testing

Yes

EUDAMED

Companion Diagnostics

No

EUDAMED

Surgical Instrument

Yes

EUDAMED

New Device

No

EUDAMED

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

No

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

No

FDA UDI

Serial Number

Yes

FDA UDI

Expiration Date

No

FDA UDI

Manufacturing Date

Yes

FDA UDI

ROTEM® sigma by TEM Innovations GmbH — Class A — IVDR, FDA UDI — listed in EUDAMED, FDA GUDID — regulatory data on deviCERTS

Authorization Coverage (2 countries)

Regulatory Authorizations

European Union Active

CE/IVDR

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

EUDAMED SRN
DE-MF-000012176

Sources (2)

  • EUDAMED 292d405f-0a5e-4655-abc4-20e2a924261f 61 fields · synced Jul 15, 2026
  • FDA UDI 14bf03af-8f48-44a6-b28a-3ea43b897da5 35 fields · synced May 30, 2026