Skip to content

Rusch Safety Clear Plus Cuffed W/Murphy Eye

by Rusch, Inc.

510(k) K925505

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK925505 Date2 Sep 1993ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
BTR
Device Class
Class II
Regulation
21 CFR Part 868.5730
Advisory Committee
Anesthesiology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This is a Tracheal Tube, Cuffed (with Connector) designed for endotracheal intubation. It features a high-volume, low-pressure cuff to ensure effective airway sealing while minimising trauma to the tracheal mucosa. The Murphy Eye design allows for ventilation through an alternative port if the primary lumen becomes obstructed, enhancing patient safety during procedures.

The device is intended for single-use and supplied in a sterile condition, ensuring compliance with clinical hygiene standards. It is non-latex and available in various sizes, including the specified Murphy Eye variant. Regulated under FDA 510(k) clearance (K925505), it adheres to Class II medical device standards (21 CFR 868.5730) and is intended for use in anesthesiology settings. Proper storage under sterile conditions is required to maintain integrity before use.

Other devices from Rusch, Inc.

See all devices from Rusch, Inc. →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary purpose of the Murphy Eye feature in this tracheal tube, and how does it improve patient safety during procedures?

    The Murphy Eye design provides an alternative ventilation port in case the primary lumen becomes obstructed. This ensures continuous airflow to the patient, reducing the risk of hypoxia and improving safety during intubation or emergency procedures.

  • Is this tracheal tube reusable, or is it intended for single-use only? What does that mean for clinical workflows?

    This device is explicitly designed for single-use only, meaning it must be discarded after one procedure to maintain sterility and hygiene standards. Clinicians should follow manufacturer guidelines to avoid reuse, as this could compromise patient safety and violate infection control protocols.

  • What sizes or models are available for this cuffed tracheal tube, and how do I determine the correct size for a patient?

    While the exact size range isn’t specified in the provided data, the device is available in multiple sizes to accommodate different patient anatomies. Selection should be based on clinical assessment (e.g., age, sex, and tracheal diameter) and institutional protocols. Always verify compatibility with the patient’s airway before use.

  • How should this tracheal tube be stored to ensure it remains sterile and intact before use?

    The device must be stored under sterile conditions as supplied to preserve its integrity. Check the packaging for expiration dates, and avoid exposure to moisture, extreme temperatures, or contamination. Once opened, it should be used immediately to prevent compromise of sterility.

  • What regulatory pathway was followed for this device, and what does that mean for its use in clinical settings?

    This tracheal tube received FDA 510(k) clearance (K925505), meaning it was determined to be substantially equivalent to a legally marketed predicate device. This clearance under Class II standards (21 CFR 868.5730) ensures it meets safety and performance requirements for use in anesthesiology settings, though clinicians should always follow local protocols and institutional guidelines.