Rymed RYM-7107HPB
Rymed RYM-7107HPB is a medical device (FDA Class II; FDA product code FPA, Set, Administration, Intravascular) made by Rymed Technologies, Inc., cleared under FDA 510(k) K991653 on 24 Jun 1999 and listed in FDA GUDID since 22 Oct 2018 (UDI-DI 00817903010797), active as of 22 Oct 2026. 4 FDA recalls are linked to it.
Active
510(k)
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00817903010797 | Date22 Oct 2018 | StatusListed |
| United States | FDA 510(k)SESE | NumberK991653 | Date24 Jun 1999 | StatusActive |
Official records
- AccessGUDID record 00817903010797
- FDA 510(k) database K991653
From the FDA record
- Device description
- 7" High Pressure Bifurcated MicroBore Catheter Extension Set with CS InVision-Plus
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied sterile; sterilise before use (Radiation Sterilization)
Across registries
- FDA 510(k) K991653 decided 24 Jun 1999 Active
- FDA GUDID UDI-DI 00817903010797 listed 22 Oct 2018 Listed
Recalls
-
- Terminated Z-0675-2016
Potential for the female luer component of the InVision-Plus IV connector to crack during use.
-
- Terminated Z-0319-2007
- Terminated Z-0320-2007
- Terminated Z-0321-2007
Weld failures on IV connector (area of female luer and spike body)
Timeline
- Cleared FDA 510(k) K991653
- Recall initiated FDA recalls Z-0319-2007
- Recall initiated FDA recalls Z-0320-2007
- Recall initiated FDA recalls Z-0321-2007
- Recall initiated FDA recalls Z-0675-2016
- Listed FDA GUDID 00817903010797
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Rymed
- Generic name
- Neutral-pressure intravenous line needleless valve-connector
- Model / reference
- RYM-7107HPB
- Primary DI / UDI-DI
- 00817903010797
- 510(k) Number
- FDA product code
- FPA
- GMDN term
- Neutral-pressure intravenous line needleless valve-connector
- Device class
- Class II
- Regulation number
- 880.5440
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Radiation Sterilization
Similar devices
Other devices filed under FDA product code FPA (Set, Administration, Intravascular).
- INFUSION SET TYPE J by Berman, Pcp & Consultants, Inc.
- SIMPLICITY EASY ACCESS INFUSION SET by Sterling Medivations, Inc.
- BURETTE-IN LINE (150 ML) by Tuta Healthcare Pty Limited
- WINGED INFUSION SET by E-Z-Em, Inc.
- IMM HYPODERMIC NEEDLE SET by Innovative Medical Manufacturing Co.
- SAF-Q-412-G24-70 by EMED Technologies Corporation
- LIFESHIELD VISION INFUSION SET WITH PRE-PIERCED RESEAL by Hospira, Inc.
- PADI-LOCK by Padi-Lock, LLC
- AMSafe-3 Non-Vented I.V. Set with 10, 15, or 60 drops/ml Selectable Drip Chamber D38303 by AMSINO INTERNATIONAL, INC.
- INTRAVSCULAR ADMINISTRATION SET by Terumo Europe N.V.