S-ROM ZTT Acetabular Cup-Apical Hole Plug

by Joint Medical Products Corp. 510(k)

Active United States

510(k) K931676

Regulatory status

as of 29 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK931676 Date18 May 1994ClearedStatusActive

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Recalls

0 recalls · FDA

No FDA recalls on record, checked 22 Oct 2026.

Specification

510(k)

Full name
S-Rom(R) Ztt(Tm) Acetabular Cup-Apical Hole Plug
510(k) Number
FDA Product Code
JDL
Device Class
Class III
Regulation
21 CFR Part 888.3320
Advisory Committee
Orthopedic
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The S-ROM ZTT Acetabular Cup-Apical Hole Plug is a Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component). This device is designed as a component of a two-part hip replacement system, intended to be implanted within the acetabulum to restore hip joint function. It features a metal construction and is secured using bone cement, providing structural support and stability in orthopedic procedures.

This device is supplied as a reusable medical implant and is intended for use in orthopedic surgical settings. It is classified as a Class III device under FDA regulations (Regulation Number 888.3320) and was granted FDA 510K clearance (K931676) in 1994. The plug is part of a semi-constrained hip prosthesis system and is not intended for MRI use. Storage and handling must comply with sterile medical device protocols, as it is implanted directly into the body.

Other devices from Joint Medical Products Corp.

See all devices from Joint Medical Products Corp. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary purpose of the S-ROM ZTT Acetabular Cup-Apical Hole Plug in a hip replacement procedure?

    The S-ROM ZTT Acetabular Cup-Apical Hole Plug is designed as a component of a two-part hip replacement system. It is implanted within the acetabulum (hip socket) to restore hip joint function, providing structural support and stability when secured with bone cement. It is part of a semi-constrained metal hip prosthesis, ensuring compatibility with other system components.

  • Is this device intended for single-use or can it be reused in multiple procedures?

    The S-ROM ZTT Acetabular Cup-Apical Hole Plug is explicitly described as a reusable medical implant. However, like all reusable implants, it must be sterilized and handled according to strict sterile medical device protocols before each use to prevent contamination and ensure patient safety.

  • What storage and handling precautions should be taken for this device?

    Since this device is implanted directly into the body, it must be stored and handled as a sterile medical implant. Proper sterile packaging and adherence to sterile medical device protocols are required to maintain its integrity before use. The manufacturer’s instructions for sterilization and storage should be followed to ensure safety and functionality.

  • Are there multiple sizes or models available for this device?

    The provided data lists multiple FEI numbers (e.g., 3020282716, 1047843, etc.), which typically correspond to different sizes, models, or variants of the device. While the exact dimensions or specifications are not detailed here, these identifiers suggest that the S-ROM ZTT Acetabular Cup-Apical Hole Plug may be available in various configurations to accommodate different patient anatomies or surgical needs.

  • Can this device be used in patients who require MRI scans after implantation?

    No, the S-ROM ZTT Acetabular Cup-Apical Hole Plug is explicitly not intended for MRI use. Patients implanted with this device should avoid MRI procedures, as metal components may pose risks such as heating, artifacts, or injury during scanning.