Identity
- Trade Name
- SAMI RRT System FDA UDI
- Generic Name
- Haemodialysis system, institutional FDA UDI
- Device Name
- The SAMI RRT Unit is a software controlled device that performs the following functions: - Primes the disposable cassette automatically, - Pumps blood through the blood flow path of the disposable cassette, - Delivers anticoagulant into the blood flow path, - Pumps sterile infusion solutions into the blood flow path of the disposable according to therapy in use, - Pumps sterile dialysate into the fluid compartment of the filter in RRT therapies, - Controls the patient fluid removal or plasma loss according to the therapy in use, - Monitors the system and alerts the operator of abnormal situations through alarms. The SAMI RRT Unit has a touchscreen interface that provides operating instructions to the user. The system is used in conjunction with the cassette tubing set. FDA UDI
- Model / Reference
- SM-100-003 FDA UDI
- Description
- The SAMI RRT Unit is a software controlled device that performs the following functions: - Primes the disposable cassette automatically, - Pumps blood through the blood flow path of the disposable cassette, - Delivers anticoagulant into the blood flow path, - Pumps sterile infusion solutions into the blood flow path of the disposable according to therapy in use, - Pumps sterile dialysate into the fluid compartment of the filter in RRT therapies, - Controls the patient fluid removal or plasma loss according to the therapy in use, - Monitors the system and alerts the operator of abnormal situations through alarms. The SAMI RRT Unit has a touchscreen interface that provides operating instructions to the user. The system is used in conjunction with the cassette tubing set. FDA UDI
Identifiers
- Catalog Number
- SM-100-003 FDA UDI
- Primary DI / UDI-DI
- B815SM1000030 FDA UDI
- FDA Product Code
- KDI FDA UDI
- GMDN Term
- Haemodialysis system, institutional FDA UDI
Classification
- Device Class
- Class II FDA UDI
- Regulation Number
- 876.5860 FDA UDI
- Commercial Distribution
- In Commercial Distribution FDA UDI
Clinical & Handling
Sterile
No
FDA UDI
Single Use
No
FDA UDI
Implantable
No
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
Yes
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
Yes
FDA UDI
Lot / Batch Number
No
FDA UDI
Serial Number
Yes
FDA UDI
Expiration Date
No
FDA UDI
Manufacturing Date
Yes
FDA UDI
Category: Haemodialysis system, institutional
SAMI RRT System by Dialco Medical Inc — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Similar devices
Also classified as Haemodialysis system, institutional.
- B.BRAUN — B.Braun Avitum AG · Class I
- Prismaflex — Gambro, Inc. · Class II
- 2008® Series Hemodialysis Machines — Fresenius Usa, Inc. · Class II
- B.BRAUN — B.Braun Avitum AG · Class II
- Molded Products, Inc. — MOLDED PRODUCTS INC. · Class II
- Molded Products, Inc. — MOLDED PRODUCTS INC. · Class II
- Molded Products, Inc. — MOLDED PRODUCTS INC. · Class II
- Molded Products, Inc. — MOLDED PRODUCTS INC. · Class II
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class II | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Dialco Medical Inc
Sources (1)
- FDA UDI da7ffc8e-5275-497c-929f-742907d04901 36 fields · synced Jun 8, 2026