Sarns 9000 Heart-Lung Console

by 3M Health Care, Sarns

510(k) K871131

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

14 closed

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 11 Oct 2026. What this means

Regulatory status

as of registry sync 11 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK871131 Date21 May 1987ClearedStatusActive

Recalls

14 recalls · FDA

  • 3 recalls, same reason

    • Terminated Z-2050-2012 FDA Class II initiated 18 Jun 2012
    • Terminated Z-2052-2012 FDA Class II initiated 18 Jun 2012
    • Terminated Z-2051-2012 FDA Class II initiated 18 Jun 2012

    Terumo Cardiovascular Systems has received several reports of malfunctions of the Air Bubble Detection System used with its heart-lung machines over the last three years. The malfunctions were expressed in various failure modes (over sensitivity, false alarms and were found to have various root causes. The malfunctions occurred in systems that were excluded from prior corrective actions or in syst

  • 9 recalls, same reason

    • Terminated Z-2618-2011 FDA Unclassified (pre-2012) initiated 3 May 2011
    • Terminated Z-2619-2011 FDA Unclassified (pre-2012) initiated 3 May 2011
    • Terminated Z-2615-2011 FDA Unclassified (pre-2012) initiated 3 May 2011
    • Terminated Z-2621-2011 FDA Unclassified (pre-2012) initiated 3 May 2011
    • Terminated Z-2616-2011 FDA Unclassified (pre-2012) initiated 3 May 2011
    • Terminated Z-2614-2011 FDA Unclassified (pre-2012) initiated 3 May 2011
    • Terminated Z-2620-2011 FDA Unclassified (pre-2012) initiated 3 May 2011
    • Terminated Z-2617-2011 FDA Unclassified (pre-2012) initiated 3 May 2011
    • Terminated Z-2613-2011 FDA Unclassified (pre-2012) initiated 3 May 2011

    The firm has recieved complaints regarding 35 pressure monitoring kits in which the membrane in the kit separated form the pressure dome housing. The firm determined that the defect was caused by a change in the pressure dome's manufacturing process.

  • 2 recalls, same reason

    • Terminated Z-0296-2009 FDA Unclassified (pre-2012) initiated 23 May 2008
    • Terminated Z-0295-2009 FDA Unclassified (pre-2012) initiated 23 May 2008

    The level sensor may not properly couple to the reservoir, resulting in a sensor "not attached" message, an alert or alarm condition, or a failure to detect a low level condition.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DTQ
Device Class
Class II
Regulation
21 CFR Part 870.4220
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Other devices from 3M Health Care, Sarns

See all devices from 3M Health Care, Sarns →