Scimed(R) 0.038 Controlwire(Tm) Peripher Guide Wir
by Scimed Life Systems, Inc. 510(k)
Active
510(k) K926457
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK926457 | Date8 Apr 1993 | StatusActive |
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Recalls
No FDA recalls on record, checked 22 Oct 2026.
Specification
- 510(k) Number
- FDA Product Code
- DQX
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.1330
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 19 Sep 2026
The Scimed 0.038 Controlwire Peripher Guide Wire is a wire, guide, catheter designed for peripheral vascular procedures. It is intended for use as a guidewire within catheters and vascular access devices to facilitate navigation through blood vessels during interventional cardiology and peripheral vascular interventions.
This device is supplied as a single-use, non-sterile item, classified under product code DQX and regulated under FDA 510(k) clearance (K926457). It is intended for use in cardiovascular settings and must be handled and stored according to manufacturer guidelines to maintain integrity. The device received FDA 510(k) clearance in 1993 under the Substantially Equivalent determination, adhering to Class II – Special Controls for wire, guide, and catheter devices.
Other devices from Scimed Life Systems, Inc.
Questions
AI-generated answers, 19 Sep 2026
What is the primary use of the Scimed 0.038 Controlwire Peripher Guide Wire in medical procedures?
This guide wire is specifically designed for use as a guidewire within catheters and vascular access devices during peripheral vascular procedures. It helps navigate blood vessels during interventional cardiology and peripheral vascular interventions, ensuring precise placement of catheters in complex or narrow vessels.
Is the Scimed 0.038 Controlwire Peripher Guide Wire intended for single-use or repeated use?
The device is explicitly labeled as a single-use item, meaning it should not be reused after one procedure. This classification aligns with standard safety practices for guidewires to prevent contamination and ensure patient safety.
How should the Scimed 0.038 Controlwire Peripher Guide Wire be stored to maintain its integrity?
Since the device is non-sterile, it must be stored according to the manufacturer’s guidelines to preserve its condition. Proper storage typically involves keeping it in a clean, dry environment away from direct sunlight or extreme temperatures, as recommended by Scimed Life Systems to prevent damage or degradation before use.
What regulatory pathway was followed for FDA clearance of this guide wire?
The device received FDA 510(k) clearance under the Substantially Equivalent (SESE) determination in 1993, classified under Class II – Special Controls for wire, guide, and catheter devices. The review was conducted by the Cardiovascular (CV) Advisory Committee, confirming its compliance with existing safety and performance standards for peripheral vascular guidewires.