Skip to content

Scimed Ultrox True Membrane Oxygen Syst, Ultrox II

by Scimed Life Systems, Inc.

510(k) K894103

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK894103 Date21 Sep 1989ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DTZ
Device Class
Class II
Regulation
21 CFR Part 870.4350
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Ultrox True Membrane Oxygen System, Ultrox II is a cardiopulmonary bypass oxygenator. It is designed to facilitate gas exchange between blood and a gaseous environment, ensuring oxygenation and carbon dioxide removal during open-heart surgical procedures. This device supports the physiological needs of patients by maintaining adequate oxygen levels and removing metabolic waste gases during extracorporeal circulation.

This system is intended for use in controlled clinical settings such as operating rooms and cardiac catheterization labs. It is supplied as a reusable medical device and has received FDA 510(k) clearance under the classification of Class II (DTZ). The device is regulated under the FDA’s regulation number 870.4350 and is associated with the Cardiovascular advisory committee. No specific sterility or MRI safety information is provided in the available data.

Other devices from Scimed Life Systems, Inc.

See all devices from Scimed Life Systems, Inc. →

Questions

AI-generated answers, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary clinical purpose of the Ultrox True Membrane Oxygen System, Ultrox II, and where is it typically used?

    The Ultrox True Membrane Oxygen System, Ultrox II, is designed specifically for cardiopulmonary bypass procedures to facilitate gas exchange between blood and a gaseous environment. This ensures oxygenation of the blood and removal of carbon dioxide during open-heart surgeries. It is intended for use in controlled clinical settings such as operating rooms and cardiac catheterization labs, where extracorporeal circulation is required to support a patient’s physiological needs during surgery.

  • Is the Ultrox True Membrane Oxygen System reusable or single-use, and what does this mean for maintenance and handling?

    The Ultrox True Membrane Oxygen System is supplied as a reusable medical device. This means it is designed to be cleaned, disinfected, and reused for multiple procedures, provided it is maintained according to manufacturer guidelines. Reusability requires adherence to strict protocols for sterilization and maintenance to ensure safety and functionality between uses.

  • What regulatory pathway was followed for FDA clearance of this device, and which advisory committee was involved?

    The Ultrox True Membrane Oxygen System received FDA clearance through a 510(k) submission, classified as Traditional, under the product code DTZ and regulated under FDA regulation number 870.4350. The device was reviewed by the Cardiovascular (CV) Advisory Committee, which provides expert input on cardiovascular-related medical devices before clearance decisions.

  • Are there multiple models or sizes available for this oxygenator system, and how would a buyer determine the correct fit for their needs?

    The Ultrox True Membrane Oxygen System includes multiple FEI numbers (e.g., 3030125051, 3021599320, etc.), which likely correspond to different configurations, sizes, or variants of the device. These variations may cater to different patient sizes, blood flow requirements, or procedural needs. Buyers should consult the manufacturer’s documentation or a medical device specialist to select the appropriate model based on clinical requirements, such as oxygenation capacity and compatibility with existing cardiopulmonary bypass systems.

  • How should the Ultrox True Membrane Oxygen System be stored, and are there any specific storage conditions mentioned in the available data?

    The provided data does not specify detailed storage conditions such as temperature, humidity, or shelf-life requirements for the Ultrox True Membrane Oxygen System. However, as a reusable medical device, it should be stored in a clean, dry environment, protected from contamination and physical damage. Manufacturers typically provide storage instructions in their technical documentation, which should be followed to maintain device integrity and functionality.