Identity
- Trade Name
- Scinus Cell Expansion System FDA UDI
- Generic Name
- Cell culture bioreactor FDA UDI
- Device Name
- The SCINUS consists of a cabinet that encloses a temperature-controlled environment where a Single Use Bag can be mounted on a mixing Rocker. At the front of the cabinet, the transparent door allows access to the internal area. When opening the transparent front door, the motor of the Rocker will be switched off. In this way, a hazardous situation is prevented. At the left side of the SCINUS front panel, the Emergency Stop button is located, together with the Illumination button and the Control Panel (touch screen display that is used as Graphical User Interface). On the top of the SCINUS, four mounting positions are available for insertion of lifting lugs. The mounting positions are covered and lifting lugs are not provided with the system. FDA UDI
- Model / Reference
- VCL3123001 FDA UDI
- Description
- The SCINUS consists of a cabinet that encloses a temperature-controlled environment where a Single Use Bag can be mounted on a mixing Rocker. At the front of the cabinet, the transparent door allows access to the internal area. When opening the transparent front door, the motor of the Rocker will be switched off. In this way, a hazardous situation is prevented. At the left side of the SCINUS front panel, the Emergency Stop button is located, together with the Illumination button and the Control Panel (touch screen display that is used as Graphical User Interface). On the top of the SCINUS, four mounting positions are available for insertion of lifting lugs. The mounting positions are covered and lifting lugs are not provided with the system. FDA UDI
Identifiers
- Primary DI / UDI-DI
- 08720299213609 FDA UDI
- FDA Product Code
- KJF FDA UDI
- GMDN Term
- Cell culture bioreactor FDA UDI
Classification
- Device Class
- Class I FDA UDI
- Regulation Number
- 864.2240 FDA UDI
- Commercial Distribution
- In Commercial Distribution FDA UDI
Clinical & Handling
Sterile
No
FDA UDI
Single Use
No
FDA UDI
Implantable
No
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
No
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
Yes
FDA UDI
Lot / Batch Number
No
FDA UDI
Serial Number
Yes
FDA UDI
Expiration Date
No
FDA UDI
Manufacturing Date
Yes
FDA UDI
Category: Cell culture bioreactor
Scinus Cell Expansion System by Scinus Cell Expansion Netherlands B.V. — Class I — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class I | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Scinus Cell Expansion Netherlands B.V.
Sources (1)
- FDA UDI 7c23bdfd-29fd-4436-978c-812aed1be14d 33 fields · synced May 30, 2026