Skip to content

Secca Tubular Electrode Device, Model A4000

by Conway Stuart Medical, Inc.

510(k) K000170

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Special NumberK000170 Date14 Feb 2000ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
GEI
Device Class
Class II
Regulation
21 CFR Part 878.4400
Advisory Committee
General, Plastic Surgery
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Secca Tubular Electrode Device, Model A4000 is an electrosurgical device designed for tissue removal and hemostasis through the application of high-frequency electrical current. It falls under the category of electrosurgical cutting and coagulation devices, intended for use in controlled tissue ablation procedures. The device operates by delivering precise electrical energy to target tissue, facilitating both excision and bleeding control in surgical settings. Its tubular electrode design allows for targeted application in specific anatomical regions.

This device is supplied as a reusable medical instrument, intended for use in sterile surgical environments. It is classified under FDA product code GEI and holds a 510(k) clearance (K000170) with a decision of Substantially Equivalent, granted under the Special 510(k) Review pathway. The device is regulated for use in general and plastic surgery procedures, adhering to FDA standards for electrosurgical instruments. No specific MRI safety information or single-use designation is provided in the regulatory data.

Other devices from Conway Stuart Medical, Inc.

See all devices from Conway Stuart Medical, Inc. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Secca Tubular Electrode Device, Model A4000 used for?

    The Secca Tubular Electrode Device, Model A4000 is an electrosurgical instrument designed for tissue removal and hemostasis. It applies high-frequency electrical current to target tissue, enabling controlled excision and bleeding control during surgical procedures. Its tubular electrode design allows for precise application in specific anatomical regions, making it suitable for general and plastic surgery applications.

  • Is the Secca Tubular Electrode Device, Model A4000 single-use or reusable?

    The Secca Tubular Electrode Device, Model A4000 is supplied as a reusable medical instrument. It is intended for use in sterile surgical environments, requiring proper cleaning, sterilization, and maintenance between procedures to ensure safety and functionality.

  • What regulatory pathway was followed for the FDA clearance of this device?

    The Secca Tubular Electrode Device, Model A4000 received FDA clearance under the Special 510(k) Review pathway. It was classified under product code GEI (Electrosurgical Cutting and Coagulation Devices) and granted a decision of Substantially Equivalent by the FDA’s General and Plastic Surgery Advisory Committee.

  • How should the Secca Tubular Electrode Device, Model A4000 be stored?

    Since this device is reusable, it must be stored in a clean, dry environment when not in use. Proper storage includes keeping it in its original packaging or a designated sterile storage area to prevent contamination. Follow manufacturer guidelines for maintenance and sterilization procedures to ensure longevity and safety.

  • Are there any specific safety considerations for using this device in MRI environments?

    The provided regulatory data does not specify MRI safety information for the Secca Tubular Electrode Device, Model A4000. Clinicians should consult the manufacturer’s instructions for use and any additional safety guidelines before using this device in proximity to MRI equipment to avoid potential risks.