Skip to content

Selenia Dimensions ASY-01986

by Hologic

Selenia Dimensions ASY-01986 is a stationary mammographic x-ray system (FDA Class II; FDA product code MUE, Full field digital,system,x-ray,mammographic) made by Hologic, approved under FDA PMA P010025 on 15 Mar 2002 and listed in FDA GUDID since 16 Nov 2017 (UDI-DI 15420045507067), active as of 23 Oct 2026. 4 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

PMA

Valid until

No expiry

PMA approval is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

PMA P010025

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number15420045507067 UDI-DI Date16 Nov 2017ListedStatusListed GUDID: in commercial distribution
United StatesFDA PMAAPRL from GUDID NumberP010025 Date15 Mar 2002DecidedStatusActive

Official records

From the FDA record

Device description
Selenia® Dimensions® compression paddles provide an optically and radiographically transparent surface to immobolize and flatten the patient breast, ensuring the highest possible image quality with minimum patient discomfort.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA PMA P010025 decided 15 Mar 2002 Active
  • FDA GUDID UDI-DI 15420045507067 listed 16 Nov 2017 Listed

Recalls

4 recalls · 1 ongoing · FDA

    • Ongoing Z-2167-2026 FDA Class II initiated 8 Apr 2026

    Complaints have been received of systems developing loose, missing, or broken internal bolts over time.

    • Terminated Z-1700-2014 FDA Class II initiated 13 May 2014

    Selenia Full Field Digital Mammography System defective relay switch, if there is a need to use the emergency off switch, the system may not turn off which could result in patient injury

    • Terminated Z-2301-2013 FDA Class II initiated 6 Sep 2013

    Software: When the Selenia upon meeting the hard drive threshold of 4,000 images, may delete the most recently dated images

    • Terminated Z-1546-2008 FDA Unclassified (pre-2012) initiated 28 Feb 2008

    Marker Misalignment: The new software version contained a magnification factor that shows CAD markers misaligned with the identified indications. The marked area is misaligned up to 2cm from the indication.

Timeline

6 dated events

  1. Approved FDA PMA P010025
  2. Recall initiated FDA recalls Z-1546-2008
  3. Recall initiated FDA recalls Z-2301-2013
  4. Recall initiated FDA recalls Z-1700-2014
  5. Listed FDA GUDID 15420045507067
  6. Recall initiated FDA recalls Z-2167-2026

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA PMA Active

Specification

GUDID

Trade name
Selenia Dimensions
Generic name
Stationary mammographic x-ray system, digital
Model / Ref / Catalog
ASY-01986
Primary DI / UDI-DI
15420045507067
PMA number
FDA product code
MUE
GMDN term
Stationary mammographic x-ray system, digital
Device class
Class II
Regulation number
892.1715
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under Stationary mammographic x-ray system, digital.

Other devices from Hologic

See all devices from Hologic →

Properties

  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (12, all answered No)