Skip to content

Senographe Pristina EKB3

by GE Medical Systems, LLC

Senographe Pristina EKB3 is a stationary mammographic x-ray system (FDA Class II; FDA product code MUE, Full field digital, system, x-ray, mammographic) made by GE Medical Systems, LLC, cleared under FDA 510(k) K172404 on 30 Oct 2017 (1 earlier submission) and listed in FDA GUDID since 23 May 2019 (UDI-DI 00840682145879), active as of 23 Oct 2026. 3 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00840682145879 UDI-DI Date23 May 2019ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK172404 Date30 Oct 2017DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K172404 decided 30 Oct 2017 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00840682145879 listed 23 May 2019 Listed

Recalls

3 recalls · 2 ongoing · FDA

    • Ongoing Z-0875-2026 FDA Class II initiated 24 Oct 2025 UDI-DI 00840682145879 listed

    Some Senographe Pristina systems either have a missing or an incorrect X-Ray Warning label, which is a nonconformance to FDA Regulation 21 CFR 1020.30(j).

    • Ongoing Z-0862-2024 FDA Class II initiated 26 Dec 2023

    X-ray exposure termination audible signal on Senographe Pristina with Efficiency Suite 2 intermittently not emitted per 21CFR 1020.31(j) requirements.

    • Terminated Z-2131-2019 FDA Class II initiated 16 May 2019

    Potential slippage of the biopsy positioner when the gantry is rotated during a biopsy procedure.

Timeline

6 dated events

  1. Cleared FDA 510(k) K162268
  2. Cleared FDA 510(k) K172404
  3. Recall initiated FDA recalls Z-2131-2019
  4. Listed FDA GUDID 00840682145879
  5. Recall initiated FDA recalls Z-0862-2024
  6. Recall initiated FDA recalls Z-0875-2026

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Senographe Pristina
Generic name
Stationary mammographic x-ray system, digital
Model / reference
EKB3
Primary DI / UDI-DI
00840682145879
510(k) Number
FDA product code
MUE
GMDN term
Stationary mammographic x-ray system, digital
Device class
Class II
Regulation number
892.1715
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under Stationary mammographic x-ray system, digital.

Other devices from GE Medical Systems, LLC

See all devices from GE Medical Systems, LLC →

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (12, all answered No)