Skip to content

Servo-c Ventilator System

by Maquet Critical Care AB

Ref 6882000

Servo-c Ventilator System (6882000) is a neonatal/adult intensive-care ventilator (EU MDR Class IIb; FDA Class II; FDA product code CBK, Ventilator, Continuous, Facility Use) made by Maquet Critical Care AB, registered in EUDAMED on 30 Sep 2025 (Basic UDI-DI 73257100031183), cleared under FDA 510(k) K192604 on 18 Jun 2020 and listed in FDA GUDID since 16 Sep 2020 (UDI-DI 07325710003114), active as of 24 Oct 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K192604

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number73257100031183 Basic UDI-DI 07325710003114UDI-DIDate30 Sep 2025RegisteredStatusActive
United StatesGUDID listing GUDID Number07325710003114 UDI-DI Date16 Sep 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK192604 Date18 Jun 2020DecidedStatusActive

Official records

From the FDA record

MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 73257100031183 registered 30 Sep 2025 Active
  • FDA 510(k) K192604 decided 18 Jun 2020 Active
  • FDA GUDID UDI-DI 07325710003114 listed 16 Sep 2020 Listed

Recalls

2 recalls · 2 ongoing · FDA

    • Ongoing Z-1568-2022 FDA Class II initiated 21 Jul 2022

    Device does not meet regulatory requirements of stability while stationary, which requires mechanical equipment, other than fixed mechanical equipment, that is intended to be used on the floor or on a table shall be permanently marked with a clearly legible warning of this risk

    • Ongoing Z-1560-2022 FDA Class I initiated 20 Jul 2022

    Ventilators may generate a combination of alarms which may result in loss of communication, technical alarms being triggered, and loss of ventilation. If the device stops ventilating due to this issue, it may lead to hypoventilation and consequently desaturation, with patient outcomes including hypoxemia and hypoxic injury, which might result in circulatory failure.

Timeline

5 dated events

  1. Cleared FDA 510(k) K192604
  2. Listed FDA GUDID 07325710003114
  3. Recall initiated FDA recalls Z-1560-2022
  4. Recall initiated FDA recalls Z-1568-2022
  5. Registered EUDAMED 73257100031183

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Servo-c Ventilator System EUDAMED
Base unit, Servo-air GUDID
Generic name
Neonatal/adult intensive-care ventilator
Device name
Servo-air Ventilator System
Model / reference
6882000
Primary DI / UDI-DI
07325710003114
Basic UDI-DI
73257100031183
Direct marketing DI
07325710003114
510(k) Number
FDA product code
CBK
EMDN code
Z1203010504 Adult and paediatric/neonatal pulmonary ventilators
GMDN term
Neonatal/adult intensive-care ventilator
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
868.5895
EU registration type
Standard device
EU market of registration
Sweden
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
SE-MF-000001264

Similar devices in this category

Other devices filed under ADULT AND PAEDIATRIC/NEONATAL PULMONARY VENTILATORS.

Other devices from Maquet Critical Care AB

See all devices from Maquet Critical Care AB →

Properties

  • Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction)
  • Administering medicine
  • Measuring function
  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (19, all answered No)