# Shiley 3.0NEF

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/shiley-3-0nef>
- Manufacturer: [Covidien LP](https://devicerts.com/manufacturers/covidien-lp) (FDA registration: United States)
- Device class: Class IIb (EU MDR / EU MDD); Class II (US FDA)
- FDA product code: JOH
- EMDN: A99 DEVICES FOR ADMINISTRATION, WITHDRAWAL AND COLLECTION - OTHER
- EMDN: R0105010101 TRACHEOSTOMIC CANNULAS, CUFFLESS, NOT REINFORCED, WITH FIXED FLANGE, AND KITS
- GMDN: Tracheostomy tube, non-reinforced, non-customized, single-use (35404)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI B-20884521779591 · UDI-DI 20884521779591 · registered 2026-06-25 · status: Active
- **EUDAMED** · CE/MDD · European Union · Basic UDI-DI B-20884521779591 · UDI-DI 20884521779591 · registered 2026-06-25 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 20884521779591 · listed 2019-05-04 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K182861 · decision 2019-03-22 · decision SESE · status: Active · from GUDID
- **GUDID** · FDA 510(k) · United States · K122531 · decision 2012-10-09 · decision SESE · status: Active · from GUDID

## Recalls

- Z-1951-2015 · Class I · terminated · initiated 2015-05-08: Reports where patients who recently switched from the current Shiley Neonatal and Pediatric products to the affected products experienced discomfort and in some cases, breathing difficulties, corresponding to a negative effect on oxygen levels.

## Identity

- Trade name: Shiley [FDA GUDID (AccessGUDID)]
- Generic name: Tracheostomy tube, non-reinforced, non-customized, single-use [FDA GUDID (AccessGUDID)]
- Device name: 3.0NEF 3.0MM ID NEO SML CUFFLESS X1 [EUDAMED]; Shiley Neonatal TT Cuffless [EUDAMED]
- Model / reference: 3.0NEF [EUDAMED, FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 20884521779591 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: B-20884521779591 [EUDAMED]; 0763000B000100875 [EUDAMED]
- 510(k) Number: K122531 [FDA GUDID (AccessGUDID)]; K182861 [FDA GUDID (AccessGUDID)]
- FDA product code: JOH [FDA GUDID (AccessGUDID)]
- EMDN code: A99 [EUDAMED]; R0105010101 [EUDAMED]
- GMDN term: Tracheostomy tube, non-reinforced, non-customized, single-use (35404) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class IIb [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 868.5800 [FDA GUDID (AccessGUDID)]
- EU registration type: Legacy device (under a directive) [EUDAMED]; Standard device [EUDAMED]
- EU market of registration: Netherlands [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Clinical & Handling

- MRI safety: MR Safe [FDA GUDID (AccessGUDID)]

## Dimensions & Sizes

- Size: Length — 30 Millimeter [FDA GUDID (AccessGUDID)]; Angle — 120 degree [FDA GUDID (AccessGUDID)]

## Properties

- Supplied sterile: Yes [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: Yes [FDA GUDID (AccessGUDID)]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Expiration date: Yes [FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Shiley 3.0NEF, Covidien LP. deviCERTS medical device catalogue. https://devicerts.com/devices/shiley-3-0nef (data as of 2026-11-16).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-23
- Statuses computed as of: 2026-11-16
- JSON: <https://devicerts.com/devices/shiley-3-0nef.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/shiley-3-0nef
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.