Si NSIN3510S
Ref NSIN3510S
Si NSIN3510S is a device classified as Class IIb in the EU and Class II in the US made by Shinhung MST Co., Ltd., registered in EUDAMED on 16 May 2026 (Basic UDI-DI B-08809457201334), cleared under FDA 510(k) K160106 on 26 Aug 2016 and listed in FDA GUDID since 10 Oct 2016 (UDI-DI 08809457201334), active as of 23 Oct 2026.
Active
CE MDD 510(k)
Valid until
No date given
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-08809457201334 08809457201334 | Date16 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number08809457201334 | Date10 Oct 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK160106 | Date26 Aug 2016 | StatusActive |
Official records
- EUDAMED public site B-08809457201334
- AccessGUDID record 08809457201334
- FDA 510(k) database K160106
Across registries
- EUDAMED Basic UDI-DI B-08809457201334 registered 16 May 2026 Active
- FDA 510(k) K160106 decided 26 Aug 2016 Active
- FDA GUDID UDI-DI 08809457201334 listed 10 Oct 2016 Listed
Timeline
- Cleared FDA 510(k) K160106
- Listed FDA GUDID 08809457201334
- Registered EUDAMED B-08809457201334
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Luna S EUDAMEDSi GUDID
- Generic name
- Screw endosteal dental implant, two-piece
- Device name
- Sterile dental implant system
- Model / reference
- NSIN3510S
- Primary DI / UDI-DI
- 08809457201334
- Basic UDI-DI
- B-08809457201334
- 510(k) Number
- FDA product code
- DZE
- EMDN code
- P01020101 Dental implants
- GMDN term
- Screw endosteal dental implant, two-piece
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 872.3640
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Türkiye
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Safe
- Size
- Length — 10 MillimeterOuter Diameter — 3.7 Millimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
| Contains latex | No | Yes |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Contains latex UDI-DI 08809457201334: EUDAMED states No, FDA GUDID states Yes.
Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.
Similar devices in this category
Other devices filed under DENTAL IMPLANTS.
- i-Clean OneQ-SL Fixture DISOF4847143 by DENTIS CO., LTD
- e-Clean tapered II Fixture DE2FW5110 by DENTIS CO., LTD
- Neobiotech Implant System ISAH535 by Neobiotech Co.,Ltd.
- Tissue Level Fixture Straight RBM TFSR4305 by AGS MEDİKAL ÜRÜNLERİ İTH. İHR. TİC. A.Ş.
- Alpha Dent Implants Dental Implants System by Alpha Dent Implants GmbH
- TA Dental Implant 2024114A by Absolute medical GmbH
- FreeMilling Abutment FMASRH45409 by Izenimplant Co.,Ltd
- K3Pro Implant/abutment screws MB.S 400030/3PRO_LS by Argon Medical Productions & Vertriebs Gesellschaft mbH & Co. KG
- Mono Implant Regular Rough MOT4520 by Novodent SA
- Angled Abutment EP-CL-CE by E-Pros Co.,Ltd.