Siemens-Elema Endocardial Lead 402S
510(k) K803042
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK803042 | Date22 Dec 1980 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DTB
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.3680
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
The Siemens-Elema Endocardial Lead 402S is a Permanent Pacemaker Electrode, classified as a Class III device under FDA regulations. It serves as an insulated electrical conductor designed to transmit pacing impulses from an external pulse generator to the heart’s endocardium, facilitating regulated cardiac rhythm.
This lead is inserted via the venous system and positioned within the heart to deliver consistent pacing signals. Supplied sterile for single-use, it adheres to FDA 510(k) clearance (K803042) under the Cardiovascular advisory committee. No MRI safety or reusable specifications are noted in regulatory records.
Other devices from Siemens Elema AB
Questions
AI-generated answers, 18 Sep 2026
What is the primary purpose of the Siemens-Elema Endocardial Lead 402S and how is it used in the body?
The Siemens-Elema Endocardial Lead 402S is designed as a permanent pacemaker electrode to transmit electrical pacing impulses from an external pulse generator to the heart’s endocardium. It is inserted through the venous system and positioned inside the heart to help regulate cardiac rhythm by delivering consistent pacing signals, ensuring proper heart function for patients with arrhythmias or conduction disorders.
Is the Siemens-Elema Endocardial Lead 402S intended for reuse, or is it meant for single-use only?
The lead is supplied sterile and explicitly labeled for single-use only. This ensures patient safety by preventing contamination or degradation from repeated sterilization or reuse, which could compromise its performance or integrity.
What regulatory pathway was followed for FDA clearance of this device, and which advisory committee was involved?
The Siemens-Elema Endocardial Lead 402S received FDA clearance through a 510(k) premarket notification process, classified as a Class III device under FDA regulations. The submission was reviewed by the Cardiovascular (CV) Advisory Committee, and the decision was determined to be substantially equivalent to a predicate device, as noted in the clearance records.
Are there any specific storage instructions or considerations for handling this device before implantation?
While the provided data does not specify detailed storage instructions, the lead is supplied sterile for single-use, so it should be stored in its original packaging until ready for use. Proper handling—such as avoiding contamination, extreme temperatures, or physical damage—is critical to maintaining sterility and functionality before implantation.